background image

7

03.1

 

PRODUCT INFORMATION

03.2

 

POWER SUPPLY FEATURES

Use AC/DC supply, LPS-type, Limited power source (according 

to IEC EN 60950-1 Ed2) or ES1, PS1-type (according to IEC EN 

62368-1)

Power supply:

 Range: +7 Vdc to +28 Vdc | Typical: 12 Vdc

Max consumption at 12 Vdc:

  140 mA

03. 

Technical characteristics 

Connector

Cable exit

Brown

Red

Grey

Blue

Yellow

Green

Orange

White

Summary of Contents for V-Reader

Page 1: ...TECHNICAL MANUAL V Reader Reader...

Page 2: ...www vauban systems fr...

Page 3: ...ORMATION 7 03 2 POWER SUPPLY FEATURES 7 03 3 FEATURES 7 03 4 OPERATING TEMPERATURE 8 04 Buzzer Led 8 05 Anti pullout function 9 06 Connection of the reader on a VERSO control unit 10 07 Configuration...

Page 4: ...ank you for purchasing a V READER reader created by the French company VAUBAN SYSTEMS Shown in our products To find out more about our range please visit our website at www vauban systems fr We wish y...

Page 5: ...at a minimum This device complies with Part 15 of the FCC and with the ISED licence without RSSs Its operation is subject to the following conditions 1 This device must not cause any dangerous interfe...

Page 6: ...ollection clean up and recycling network from DEEE established by ESR RECYLUM to which the manufacturer has adhered and to which he transfered his regulatory obligations as a producer We suggest the o...

Page 7: ...e Limited power source according to IEC EN 60950 1 Ed2 or ES1 PS1 type according to IEC EN 62368 1 Power supply Range 7 Vdc to 28 Vdc Typical 12 Vdc Max consumption at 12 Vdc 140 mA 03 Technical chara...

Page 8: ...L L Connector exit 8 female contacts 28 22 AWG to be crimped Wurth Electronik 62400113722DEC Double row female connector with 8 points Wurth Electronik 624008213322 Use a crimping tool WURTH ELEKTRONI...

Page 9: ...he pullout is detected by an accelerometer Once it is detected The reader will perform the operations configured in VISOR Note turn on the reader when it is in its final position to start the accelero...

Page 10: ...ng an external power supply to pow er your proximity scanners ensure that you connect all grounds to the ground on the control unit 06 Connection of the reader on a VERSO control unit 12V red GND brow...

Page 11: ...supply on the VERSO side The connection of an end of the line resistance of 120 must be performed on the V READER side the 2 resistors of 1 5K must be installed on the central unit side A and B signa...

Page 12: ...nsion The perturba tions they can cause vary according to their radiation power and their proximity to the readers Distance between the 2 readers parallel planes 30 cm same plane 40 cm perpendicular p...

Page 13: ...n VISOR V2 0 0 30 minimum and the firmware of the control unit must be V3 5 at a minimum 07 2 V READER 07 Configuration on VISOR Note Configuration on VISOR V2 0 0 33 minimum and the firmware of the c...

Page 14: ...base clip the higher part and then move it downwards Fix the reader with 2 screws and the connec tor that was provided 08 Fixation Pass through the cables on the base cavity Fix the base on its final...

Page 15: ...15 V READER KP fixation base...

Page 16: ...16 10 Free installer hotline A technical question Contact our free hotline...

Page 17: ...Saint Christophe 7 rue du petit Albi 95800 Cergy FRANCE VAUBAN SYSTEMS Lyon 1 rue du Dauphin 69120 Vaulx en Velin FRANCE Telephone Office 33 0 1 30 27 25 35 Fax 33 0 1 30 27 21 72 Email Contact vauba...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...www vauban systems fr AN AFFILIATE OF THE GROUP...