![VAT LINVAT 070 Series Installation, Operating, & Maintenance Instructions Download Page 18](http://html1.mh-extra.com/html/vat/linvat-070-series/linvat-070-series_installation-operating-and-maintenance-instructions_3663031018.webp)
MAINTENANCE
Series 07
18/27
Edition 2020-05-07
891111EB.DOCX
6.3
Replacement of gate
NOTICE
Wrong tightening torque
Door body and screws may get damaged.
Use tightening torque according to size of the screws.
NOTICE
Contamination
Product may get contaminated.
Always wear cleanroom gloves when handling the product.
NOTICE
Inappropriate tools
Sealing surfaces may get damaged.
Do not use sharp-edged tools.
1. Vent chambers.
2. Open the door.
3. Disconnect electrical power supply.
4. Disconnect compressed air supply.
5. Loosen the screw for the gate (2), use convenience tool (1), see «Figure 6-2» on page
19.
6. Grasp the gate (2), by using the convenience tool (1) into the M8 thread, see «Figure
6-2» on page 19.
7. Remove the gate (2) carefully, if necessary wiggle gently, use convenience tool (1),
see «Figure 6-2» on page 19.