7.2.2
Replace the actuator
7.2.2.1
Required tools
•
Allen wrench 2.5 mm
•
Allen wrench 3 mm
•
Allen wrench 4 mm
•
Pozidriv screwdriver No.1
•
CPA 4.0 (in EC2 integrated)
Electrical power is required.
Description
Required tool
1. Use the description of chapter
«7.2.1 Removing the plate and
plate seal replacement to remove
the plate. Only steps 1 to 9 are
needed.
2. Place the plate on a clean surface.
3. Switch ON the power supply.
4. Select [LOCAL].
CPA
5. Enter the SFV Axis Initialization
Mode: Parameters > Valve > SFV
Axis Initialization Mode > True,
press save button or [Enter] on
keyboard
6. Switch OFF the power supply.