Installation, Operating, and Maintenance Instructions 

Series 64.1

 

 

 

 

 

VAT Vakuumventile AG, CH-9469 Haag, Schweiz 

Tel ++41 81 771 61 61   Fax ++41 81 771 48 30   Email [email protected]   http://www.vatvalve.com

 

283681EB

 

2011-03-18 

12/19 

 

 

Problem 

Recommendation 

RS485 interface installed: 
Controller does not respond to 
RS485 commands 

-  Verify settings of the switch S1 on the RS485C interface are correct 
-   Confirm that RS485C interface is installed correctly 
  ‘RS485’ is displayed on the LCD display during start-up  
-  Confirm that PM controller is in REMOTE 
-  Logic inputs on RS485 interface override RS485 commands 

RS485 interface installed: 
Controller responds with error message 

-  Wrong command or transmission error, see chapter ‚9.2 RS485 Interface‘ 

 
 
 

7 Repairs 

Contact VAT for repair. Please check first  the fabrication No. 641P . - . . . . . - . . . .  - . . . .) marked on the rear panel of the 
PM controller.  Your VAT representative will discuss with you how the repair can be carried out best. 
 
 
 

8 Warranty 

Each product sold by VAT Vakuumventile AG (VAT) is warranted to be free from the manufacturing defects that adversely 
affect the normal functioning thereof during the one-year period immediately following delivery thereof by VAT, provided 
that the same is properly operated under conditions of normal use and that regular, periodic maintenance and service is 
performed or replacements made, in accordance with the instructions provided by VAT. The foregoing warranty shall not 
apply to any product or component that has been repaired or altered by anyone other than an authorized VAT 
representative or that has been subject to improper installation or abuse, misuse, negligence or accident. VAT shall not be 
liable for any damage, loss, or expense, whether consequential, special, incidental, direct or otherwise, caused by, arising 
out of or connected with the manufacture, delivery (including any delay in or failure to deliver), packaging, storage or use of 
any product sold or delivered by VAT shall fail to conform to the foregoing warranty or to the description thereof contained 
herein, the purchaser thereof, as its exclusive remedy, shall upon prompt notice to VAT of any such defect or failure and 
upon the return of the product, part or component in question to VAT at its factory, with transportation charges prepaid, and 
upon VAT's inspection confirming the existence of any defect inconsistent with said warranty or any such failure, be entitled 
to have such defect or failure cured at VAT's factory and at no charge therefor, by replacement or repair of said product, as 
VAT may elect. VAT MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESS OR IMPLIED, 
(INCLUDING NO WARRANTY OR MERCHANTABILITY), EXCEPT FOR THE FOREGOING WARRANTY AND THE 
WARRANTY THAT EACH PRODUCT SHALL CONFORM TO THE DESCRIPTION THEREOF CONTAINED HEREIN, and 
no warranty shall be implied by law. 
Furthermore, the «Terms of sale» at the back of the price list are applicable. 
 

Summary of Contents for 64.1 Series

Page 1: ...enance Instructions IOMI and the enclosed General Safety Instructions carefully before you start any other action Table of content 1 Intended Use of Product 2 1 1 Technical Data 2 2 Installation 2 2 1...

Page 2: ...ranges specified below 1 1 Technical Data Mains voltage 100 240 VAC 10 50 60 Hz Temperature 0 50 C Sensor input signal 0 10 VDC max Sensor power supply 15 VDC 5 1400 mA max total current for sensor 1...

Page 3: ...er 9 1 2 Connector for mains 5 Interface cable wiring information see chapter 9 1 3 Connector for RS485 interface 6 Sensor 1 standard and 2 option 7 Cable for sensor 1 and 2 wiring information see cha...

Page 4: ...higher than 1 of sensor full scale Evacuate process chamber to high vacuum When the base pressure is reached send RS485 command 000Z CR LF 9 2 4 RS485 Control commands Disable ZERO function in SENSOR...

Page 5: ...t value Store the set point value by pressing one of the four SET POINT keys for at least 2 seconds Freeze valve position interrupt pressure control While in PRESSURE MODE press F1 key to interrupt pr...

Page 6: ...ontrollers PM 2 3 PM 4 5 and PM 7 7E PM Controller with previous SRAM IC3 version see chapter 4 2 PM Controller with actual SRAM version see chapter 4 3 IC3 SRAM IC3 Socket Part No Part No SRAM batter...

Page 7: ...for battery pack disconnect connector of battery pack install new battery pack and install connector for battery pack Reattach covers Attach new label and mark on label new expiration date 5 years af...

Page 8: ...tile AG CH 9469 Haag Schweiz Tel 41 81 771 61 61 Fax 41 81 771 48 30 Email reception vat ch http www vatvalve com 283681EB 2011 03 18 8 19 4 Remove cover plate 5 Remove the battery carefully from the...

Page 9: ...tenance Instructions Series 64 1 VAT Vakuumventile AG CH 9469 Haag Schweiz Tel 41 81 771 61 61 Fax 41 81 771 48 30 Email reception vat ch http www vatvalve com 283681EB 2011 03 18 9 19 4 4 Power fail...

Page 10: ...urrounding temperature is not higher than 30 C A significant decrease is directly linked with higher temperatures The following diagram shows the influence on life time at various ambient temperatures...

Page 11: ...is closed and does not respond to RS 485 or keyboard commands Logic CLOSE input on RS 485 interface is active Pressure reading is wrong Negative pressure reading Confirm that sensor setup is correct...

Page 12: ...d or replacements made in accordance with the instructions provided by VAT The foregoing warranty shall not apply to any product or component that has been repaired or altered by anyone other than an...

Page 13: ...or signal 8 Sensor signal 10 15 VDC max 5 1400 mA max 12 0 VDC 14 15 VDC max 5 1400 mA max total current for both sensors is 1400mA Mind Do not connect other Pins than indicated in the table above Rec...

Page 14: ...t Valve opens when contact PIN 17 to 23 is closed Logic inputs CLOSE valve and OPEN valve are executed in REMOTE and LOCAL operation These signals have priority CLOSE is higher than OPEN and they are...

Page 15: ...2 nd acknowledgement Answer enabled disabled Immediately after receipt of the command the PM controller will send an acknowledgement that the command has been received Please refer to section 9 2 2 R...

Page 16: ...d by one or two acknowledgements 1st acknowledgement Confirmation that command has been received within a maximum of 40 ms 2nd acknowledgement If enabled confirmation that command has been executed Lo...

Page 17: ...0 CR LF up to 100 1 1000 10 Pressure command S Standard command xxxx 0000 to 1000 Pressure in 1 1000 of full scale 000S 00xxxx CR LF 000S CR LF 000S CR LF 000S 000119 CR LF 119 1 1000 of sensor full s...

Page 18: ...E Self test 000T CR LF 000T ____OK CR LF 000T PAR ER CR LF 000T ROM ER CR LF memory o k parameter error EPROM error see section 6 Trouble Shooting if PAR ER or ROM ER appears Sensor zero offset in 1 1...

Page 19: ...Position Mode only 2 pressure display in Torr d Gain Factor 0 1 00 1 1 33 2 1 78 3 2 37 4 3 16 5 4 22 6 5 62 7 7 50 8 0 1 9 0 13 A 0 18 B 0 23 C 0 32 D 0 42 E 0 56 F 0 75 0 Gain factor 1 00 e Sensor T...

Page 20: ...mode or with S Command Pressure control starts after PRESSURE MODE and a SET POINT is selected or after a pressure control command is sent to the PM controller 9 3 2 How to optimize sensor signal res...

Reviews: