4.2.1
Preparation for installation
WARNING
Danger of injury in case of insufficient skills
Inappropriate handling may cause serious injury or property damage.
Make sure that the valve does not topple or fall down while removing the
protective covers from the flanges.
NOTICE
Sensitive product
Valve parts may get damaged.
When removing the protective covers from the flanges, be careful to avoid
damage to the valve.
1. Remove plastic bag.
2. Remove screws, Nuts and protective covers
3. Remove O-rings.
Store protective covers, O-rings, nuts and screws. They may be useful when
valve needs to be repacked.
4. Clean sealing surfaces with cleanroom wiper soaked with pure alcohol (Isopropanol).
5. Clean sealing surface with clean, oil free compressed air.