OPERATION
Series 47
16/28
Edition 2018-11-05
600243EC
5
Operation
WARNING
Unqualified personnel
Inappropriate handling may cause serious injury or property damage.
Only qualified personnel are allowed to carry out the described work.
WARNING
Movable parts
Human body parts may get jammed and severely injured.
Do not operate before product is installed completely into the vacuum system.
5.1
Normal operation
Valve is closed and opened pneumatically.
For technical details, see product data sheet.
Make sure that compressed air is supplied at the specified pressure;
see also chapter «0 Compressed air connection».
Make sure that the connect voltage is supplied.
Check voltage specification on coil; see also chapter «4.3 Electrical
connection».
Action
Execution
Procedure
To open
the valve
Without solenoid
valve
47 ... - . E14- ....
47 ... - . E24- ....
47 ... - . E72- ....
Supply compressed air to connection “open”.
Release air through connection “closed”.
Standard solenoid
valve
47 ... - . E44- ....
47 ... - . E74- ....
Supply specified voltage to the magnetic coil.
Impulse solenoid
valve (option)
47 ... - . E44- ....
47 ... - . E74- ....
Supply an impulse of specified voltage to the coil for
opening (pulse duration min. 50 ms).
Table 5-1