4.1.2  Replacement of plate seal 

 
 

  Pick O-ring (61) with a needle and pull it out of groove 

Attention: Do not damage the sealing surface! 

 

  Check condition of sealing surface and clean it with alcohol 

 

  Put new O-ring (61) on gate groove and press it into groove, in crosswise order, at 4 locations 

 

  Press whole O-ring uniformly into groove 

 
4.1.3  Installation of "actuator/gate assembly"  
 
 

  Check condition of sealing surfaces at bonnet and valve seat and clean sealing surfaces with alcohol 

 

  Put bonnet seal (62) into groove 

 

  Carefully insert "actuator/gate assembly". Do not cant! 

 

 

Insert all bonnet screws (60) finger tight. Once all screws are finger tight, tighten each screw 
1/8th of a turn in a cross wise action using an appropriate torque wrench / allen key. Repeat 
the process until all screws are tight taking care not to exceed the maximum torque of

 

DN 16 25 40 63 

Nm 

4 4 10 

12 

 

 

  Perform function and leak test 

 

5 Drawing 

 

1

)

 

 
1) Please make sure that the bonnet seal is mounted like shown. 
 

Summary of Contents for 284 Series

Page 1: ...label below or similar made in Switzerland Fabrication No patented 284 A Fabrication number Explanation of symbols Read declaration carefully before you start any other action Keep body parts and obj...

Page 2: ...ay photocopies microfilms or any other reproduction processes nor may it be manipulated with electronic systems duplicated or distributed without written permission from VAT Offenders are liable to pa...

Page 3: ...11 07 14 3 8 Contents 1 Use of product 4 1 1 Technical data for standard valve 4 2 Installation 5 2 1 Unpacking 5 2 2 Installation into the system 5 3 Operation 5 3 1 Normal operation 5 3 2 Operation...

Page 4: ...er applications are only allowed with the written permission of VAT 1 1 Technical data for standard valve Leak rate body 5 10 10 mbar ls 1 valve seat 1 10 9 mbar ls 1 Pressure range 1 10 10 mbar to 5b...

Page 5: ...immediately before the valve is mounted into the system Unprotected sealing surfaces must be treated with care and kept clean 2 2 Installation into the system DN nom I D Axial tensile or compressive f...

Page 6: ...Fabrication number has always to be specified All supplies e g compressed air electrical power must be disconnected for removal installation of the valve from into the system and for maintenance work...

Page 7: ...roove in crosswise order at 4 locations Press whole O ring uniformly into groove 4 1 3 Installation of actuator gate assembly Check condition of sealing surfaces at bonnet and valve seat and clean sea...

Page 8: ...an authorized VAT representative or that has been subject to improper installation or abuse misuse negligence or accident VAT shall not be liable for any damage loss or expense whether consequential...

Reviews: