![VAT 09.1 Series Installation, Operating, & Maintenance Instructions Download Page 16](http://html1.mh-extra.com/html/vat/09-1-series/09-1-series_installation-operating-and-maintenance-instructions_855855016.webp)
MAINTENANCE
Series 091
16/27
Edition 19.05.2021
1088779EA
7.3
Cleaning of the valve gate and body
WARNING
Loaded spring steel sheet
Human body parts may get jammed and severely injured.
Do not put human body parts between valve gate and spring steel sheet.
NOTICE
Contamination
Product may get contaminated.
Always wear cleanroom gloves when handling the product.
NOTICE
Inappropriate tools
Sealing surfaces may get damaged.
Do not use sharp-edged tools.
Do not clean the O-ring with alcohol, because alcohol may damage the surface of the
O-rings, we recommend to treat the O-rings with a small amount of vacuum grease.
1.
Vent chambers on either side of the valve to atmospheric pressure.
2.
Open the valve.
3.
Disconnect compressed air supply.
4.
Disconnect electrical power supply.
5.
Remove screws (1); see «Figure 7-1» on page 17.