2) 

Slide the square post, with the center hole at 

the bottom and the (2) 5/16” bolts/floating nuts 
at the top, into the square hole created by the 
legs. Insert the 1/4-20 x 2 1/4” lg. hex head bolt 
through legs and square post and fasten with 
1/4” serrated lock nut. Tighten with a 7/16” 
wrench. Evenly tighten all hardware in the as-
sembly. (Do not over tighten.) 
 

3) 

Turn the assembly over and install four level-

ers or (optional) casters, one at the end of each 
leg with (4) 3/8” nuts and washers. Tighten us-
ing 9/16” wrench. 
 

4)

 Loosen slightly both 5/16” bolts, only enough 

for the round post to slide past. Install round 
post into square post. Slide the post down until 
the end can be seen through the site window. 
Tighten both 5/16” bolts to secure the round 
post.   

Do not over tighten bolts. 

 
5) 

Thread the knob into the lock collar and in-

stall the lock collar onto the post. Position the 
lock collar 6" (15 cm) down from the top of the 
post and tighten knob fully.  
 

6) 

Unpack the heater head assembly and uncoil 

the line cord. 

Be careful not to damage the heater surface! 
 
7) 

Attach 3 handles, one to each side of the heat-

er head with (12) #8 x 3/8” sheet metal screws 
using 1/4” wrench.  
 

8) 

Carefully slide the heater head over the post 

to rest onto the vertical adjustment locking    
collar.

 

1) 

Position the legs as shown below and bolt 

together with 1/4” bolts and serrated lock nuts. 
Do not fully tighten at this time.  

Tools Required: 

1/4” Wrench or nut driver 
7/16”, 1/2” & 9/16” Wrench 
Adjustable Wrench  

Square Post 

Cross Bolt 1/4” x 2-1/4” lg. 
& lock nut 

Flash Head 

Handles 

Round Post 

Vert. Adjustment 
Locking Collar 

Square Post 

Site Window

 

(see enlarged view) 

Levelers or 

Optional Casters 

5/16” Bolts & 

Floating Nuts 

Spec. Tag 

Assembly Instructions 

Site Window 

(Enlarged View) 

Square Post 

Round Post 

4

Summary of Contents for F-100

Page 1: ... Drawing ____________________ Rev _______ Serial ________________________ Date ____ ____ ____ Contents Page Component Identification 2 Safety Information 3 Assembly 4 Electrical Requirements 5 Controls 5 Operation 5 Maintenance and Troubleshooting 6 Warranty Terms and Conditions 7 Original Instructions Vastex International Inc 7 Emery St Bethlehem Pa 18015 Phone 610 625 2702 Web Site www vastex co...

Page 2: ...4 3 8 16 Threaded Levelers 04 06 027 3 Handles 07 04 016 0 8 8 x 3 8 Sht Metal Screws 04 05 080 4 3 8 16 Hex Nuts 04 05 285 1 Heater Head 1 Round Post Part 07 04 007 0 4 Legs Part 07 01 011 1 Square Post Part 07 04 008 0 07 04 009 0 Inspect all packages while unpacking and notify the shipping company if any damages are detected The flash heater head was assembled tested burned in and packaged in p...

Page 3: ... is switched off and locked out No unauthorized persons are to be allowed inside the control boxes Turn off and lock out power at the main disconnect before cleaning and maintenance Only qualified technicians should be allowed to make repairs on VASTEX Flash Units Noise and vibration These units do not pro duce noise exceeding 70 dB A Warning Heat Control and or power switch should be switched off...

Page 4: ...Thread the knob into the lock collar and in stall the lock collar onto the post Position the lock collar 6 15 cm down from the top of the post and tighten knob fully 6 Unpack the heater head assembly and uncoil the line cord Be careful not to damage the heater surface 7 Attach 3 handles one to each side of the heat er head with 12 8 x 3 8 sheet metal screws using 1 4 wrench 8 Carefully slide the h...

Page 5: ...prox 20 min Shutdown Turn off power switch or heat control Switch off circuit breaker Unplug flash unit Operation The FLASH will effectively flash dry all types of plastisols and thermoset inks Set the control to position 5 and a distance of 2 3 from the face of the heater to the surface of the garment The normal dwell time under the heater is the time you spend printing another garment Neverthele...

Page 6: ...000 F 1000 240 F100 F 100 240 all models Machine unplugged Faulty temperature controller Faulty power switch Faulty heater Plug into appropriate outlet Contact Vastex for assistance Contact Vastex for assistance Contact Vastex for assistance Heat on cannot be controlled F1000 F 1000 240 Faulty temperature controller Contact Vastex for assistance Symptom Possible Cause Solution Troubleshooting Char...

Page 7: ...or licensed trucker shall constitute delivery to Buyer and be determinative of the date and time of shipment and all risk of loss or damage in transit shall be borne by Buyer If the Buyer fails to accept the goods from the common carrier or licensed trucker the Seller shall be entitled to claim payment from the Buyer Seller shall arrange for storage the risk and the cost including insurance costs ...

Reviews: