The ventilation unit should be inspected periodically for contamination.
The ventilation unit should be switched off for inspection by making the unit
free of voltage. The ventilation unit contains rotating mechanical components.
If you make the unit free of voltage, these components continue to rotate for
a few seconds. Therefore, wait approx. 20 seconds after switching off the unit
until the components stop rotating. The user should check that the installer
periodically maintains the complete installation.
Make sure that no one else can make the unit ‘live’ before you have
finished your work activities. Turn the voltage back on only after the
ventilation unit is installed and all components are mounted.
Vasco is not liable for damage caused by non-compliance with the safety
regulations or by not observing the instructions in the user manual. You will
find the warranty conditions on page 20 of this manual.
This ventilation unit, including heat recovery, is intended for ventilating houses.
Specific characteristics of this ventilation unit are:
1. The
heat exchanger
with very high yield ensures optimal heat transfer
from the hot contaminated exhaust air to the cooler freshly supplied
outdoor air. The two airflows do not come in contact with each other.
On the other hand, the heat exchanger will cool the hot outdoor air to the
cooler indoor air during hot periods.
2.
Electrostatic air filters
, which have a double function, have been fitted
into the two airflows. The first function is filtering the fresh air in which
pollen and coarse and fine dust particles are intercepted. The second
function is protecting the ventilation unit against contamination.
The filters also have an anti-bacteriological function.
3. On the one hand, the
two energy-efficient DC ventilators
ensure the
supply of fresh outdoor air to the living room and bedrooms and on the
other hand, the exhaust of contaminated indoor air from the kitchen,
bathroom, toilet(s) and possibly the storage room.
4. An
automatic antifreeze protection
ensures that the ventilation unit
can function frost-free, guaranteeing good ventilation during the winter
period.
5. The ventilation unit can be operated in different ways:
- In three (3) positions by means of the
wireless 3-position switch
-
Demand-driven
via sensors in the RF switches
MAINTENANCE
WARRANTY
OPERATION
3 MANUAL FOR THE USER
OPERATION
OPTIONS
OPERATION OPTIONS 03
02 OPERATION
RF SWITCH
The ventilation unit can only be operated by a linked switch. Page 13 of this
manual provides more instructions about connecting the switch. A standard
feature is that the ventilation unit has a connected RF switch, including a LED
indicator.
Button
Description
Press once
Unit operates in position 1 (low).
Vasco recommends using this position during periods
of absence.
Press once
Unit operates in position 2 (medium).
This is the standard position during periods of
presence
Press once
Unit operates in position 3 (high).
This is the recommended position during showering or
bathing. It can also be used in case of extra ventilation
(visitors, family parties, etc.).
Press once
Unit operates in position 3 for 30 minutes.
After this period, the unit will switch to the previous
position. Pressing a position will prematurely end
this operation
Press for 3 seconds Unit operates in the automatic position.
If you combine the ventilation unit with a CO2
switch, then the ventilation unit switches to the
automatic position.
There is a LED in the center of the switch. This LED will turn green once the
requested position is communicated.
Position 1
Position 2
Position 3
Timer function
NL
FR
DE
EN
IT
PL