4. From the top of the fixture, slide the lens behind the lens catchers and position its base behind
the tabs on the bottom of the lens rotation ring.
5. gently push the top of the lens inward until it snaps behind the spring clip.
6.2.
Removing a lens
Warning! Unplug the fixture before attempting to remove or install a lens.
1. Source CDM PAR lenses get hot while the unit is in operation. Let the fixture cool before
handling the lens.
2. Place the fixture on a flat, stable work surface. Do not install or remove lenses with the unit
hanging.
3. Position the lens rotation ring with the spring clip at the top of the unit, directly below the
retaining clip.
4. Tilt the front of the fixture down at least 45°
5. press the spring clip with your finger to release the lens (Figure 4)
6. allow the lens to drop forward from under the clip
7. when the lens drops, remove your finger, allowing the lens to slide forward until it rests on the
lens catchers (Fifure 5)
8. Carefully remove the lens from the fixture.