7 / 16
3. Introduction
Thank you for buying the LED Street Bar 16x3W RGB IP65.
It is a powerful device.
For a successful installation and operation, please read this manual carefully.
4. Connections
4.1. Electrical connections
If you wish to change the power supply settings, see the chapter Appendix. Connect the fixture to the
mains with the enclosed power cable and plug. The earth has to be connected.
Cable (EU)
Cable (US)
Pin
International
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
4.2. DMX connections
To make a DMX512 connection go ahead like it is described in the picture. Make sure that you use
shielded cable. 3pole or 5pole XLR cables are suitable. If you use a controller with a 5 pin DMX output
connector, you will need to use a 5pin to 3 pin adapter.
4.3. DMX connection with terminator
Where the DMX cable has to run a long distance or the equipment is operated in an electrically noisy
environment like a disco for installations, we recommend using a DMX terminator. This prevents
corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR
connector with a 120
Ω
resistor between pins 2 and 3, which is then plugged into the XLR output
socket of the last device in the series. Please look to the bottom drawings.