Varytec LED PAD 147 User Manual Download Page 4

 

4 / 8 

Important:  

Damages caused by the disregard of this user manual are not subject to 

warranty. The dealer will not accept liability for any resulting defects or 

problems. Make sure the electrical connection is carried out by qualified 

personnel. All electrical and mechanical connections have to be carried out 

according to the European safety standards. 

 

2.  Technical Data 

 

Power supply 

100 - 240V  50/60Hz 

Power consumption 

15W 

Current 

0.1A 

Sound to Light 

Via built in mic 

DMX512 connection 

3 Pin XLR 

Weight 

2,1  Kg 

Measurements 

273 x 265 x 79mm 

Maximum ambient temperature 

-20° - +40°C 

Maximum housing temperature 

+20° - +60°C 

Fuse 

F1A, 250V 

Channel 

Number of LEDs 

147 x 10mm LEDs (51R, 48G, 48B) 

Beam angle 

25° 

 

 

3.  Operation 

3.1. DMX Control 

To set up your desired DMX address, you have to set up the dipswitch on the backside as follows: 

Set the dip 10 to OFF 

With all the other dipswitches 1 to 9 you can set up the DMX address regarding the binary 

system. In this system each dip has a value, which you have to add to get the dmx address. 

Dip 

Wert 

16 

32 

64 

128 

256 

If you want to set the address 10 then you have to setthe dips 4 and 2 to ON, because theire 

values are 2 and 8 and 2+8=10. 

Remember that the item needs 6 channels. 

So if you want to set the first item to address 1, the second item has to be minimum address 7, 

because 1+6=7. 

 

 

 

 

 

 