NOTICE!
Risk of fire
Do not block areas of ventilation. Do not install the device near any direct heat

source. Keep the device away from naked flames.

NOTICE!
Voltage supply
Connect the device directly to the power grid. It must not be connected to a

dimmer.
Before connecting the device, you have to ensure that the rated voltage indicated

on the device matches the voltage of the power grid available in the operating

place. You must also take care that the power grid is protected by a residual cur‐

rent circuit breaker. Failure to do so can result in damage to the device and injury

to the user.
In case a thunderstorm is coming up or you're not going to use the device for a

longer period of time, disconnect it from the power grid to reduce the risk of elec‐

tric shock and fire.

Safety instructions

 

12

Area Flood 30 IP, Area Flood 50 IP, Area Flood 80 IP, Area Flood 100 IP

LED floodlight

Summary of Contents for Area Flood 100 IP

Page 1: ...Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP LED floodlight User manual...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 10 02 2020 ID 472585 472586 472587 472588...

Page 3: ...bols and signal words 7 2 Safety instructions 9 3 Features 13 4 Installation and starting up 15 5 Technical specifications 18 6 Cleaning 26 7 Protecting the environment 27 Table of contents Area Flood...

Page 4: ...4 Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP LED floodlight...

Page 5: ...g this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We there fore reserve t...

Page 6: ...the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal cons...

Page 7: ...death or serious injury if it is not avoided WARNING This combination of symbol and signal word indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoid...

Page 8: ...e of danger Warning high voltage Warning dangerous optical radiation Warning suspended load Warning danger zone General information 8 Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100...

Page 9: ...will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding knowledge and exp...

Page 10: ...the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where high voltages may be present Nev...

Page 11: ...rectly into the light source DANGER Possible danger caused by damaged front glass Damaged front glass can result in injuries caused by falling glass fragments Furthermore moisture could penetrate into...

Page 12: ...device matches the voltage of the power grid available in the operating place You must also take care that the power grid is protected by a residual cur rent circuit breaker Failure to do so can resu...

Page 13: ...llumination n High luminous power with low power consumption n Outdoor use due to protection class IP65 For technological reasons the light output of LEDs decreases over their lifetime This effect inc...

Page 14: ...nd not for permanent use outdoors The specified protection class does not make a statement about the weather resistance of the equipment resistance to changing ambient conditions as well as against th...

Page 15: ...nal packaging or your own packaging material suitable for transport or storage respectively WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards...

Page 16: ...s in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand You can install the unit in hanging or standing position When in us...

Page 17: ...ached to the bracket Please note that this device must not be connected to a dimmer Create all connections while the device is off Use the shortest possible high quality cables for all connections Tak...

Page 18: ...utput approx 110 lm watt Lifetime LED chip approx 20 000 hours Optical properties Beam angle 120 symmetrical Input connections Voltage supply Power cable with safety plug 120 cm Power consumption 30 W...

Page 19: ...tal 192 mm 172 mm 92 mm Weight 1 8 kg Ambient conditions Temperature range 30 C 50 C Relative humidity 50 non condensing Technical specifications Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Are...

Page 20: ...20 000 hours Optical properties Beam angle 120 symmetrical Input connections Voltage supply Power cable with safety plug 120 cm Power consumption 50 W Operating supply voltage 100 240 V 50 60 Hz Prot...

Page 21: ...Ambient conditions Temperature range 30 C 50 C Relative humidity 50 non condensing Technical specifications Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP 21 LED floodlight...

Page 22: ...20 000 hours Optical properties Beam angle 120 symmetrical Input connections Voltage supply Power cable with safety plug 120 cm Power consumption 80 W Operating supply voltage 100 240 V 50 60 Hz Prot...

Page 23: ...Ambient conditions Temperature range 30 C 50 C Relative humidity 50 non condensing Technical specifications Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP 23 LED floodlight...

Page 24: ...approx 20 000 hours Optical properties Beam angle 120 symmetrical Input connections Voltage supply Power cable with safety plug 120 cm Power consumption 100 W Operating supply voltage 100 240 V 50 60...

Page 25: ...50 non condensing Outdoor ready Yes Colour mixture CW Floor housing No Fanless Yes Remote control Not possible Wireless DMX No Housing colour black Further information Technical specifications Area Fl...

Page 26: ...on the operating environment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using our lamp and lens cleaner item...

Page 27: ...ng This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Dispose of this devic...

Page 28: ...Notes 28 Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP LED floodlight...

Page 29: ...Notes Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP 29 LED floodlight...

Page 30: ...Notes 30 Area Flood 30 IP Area Flood 50 IP Area Flood 80 IP Area Flood 100 IP LED floodlight...

Page 31: ......

Page 32: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Reviews: