INSPECTIONS AND MAINTENANCE
6 INSPECTIONS AND MAINTENANCE
6.2 Maintenance Servicing
Observance of maintenance intervals is recommended to ensure the appropriate working conditions.
•
GEARBOXES
According to working conditions:
Eliminate by means of a vacuum cleaner any dust accumulation thicker than 5 mm
Every 500 working hours or every month:
Oilseal visual check to monitoring any lubricant leakage.
Every 3000 working hours or every 6 months:
Oilseal check and replacement if considerably used.
Every 5 years:
Replace synthetic oil.
•
VARIATORS
For variators VR only, please also consider the following prescriptions in addition to the above ones
According to working conditions:
Replace friction ring, if considerably used.
Every 3000 working hours or every 6 months:
Check output shaft angular play and oilseal and corrugated hood integrity.
Every 6000 working hours or every year:
Replace friction ring.