Safety Instructions 

 

  Read the Safety Instructions carefully and keep it for use later. 

 

  The chassis metalwork of the module must be installed properly to the main earthing termination 

for Class 1 equipment. 

 

  Care must be exercised in the application of the system to prevent overheating. Ensure that the 

ambient temperature around the system does not exceed 60°C and provide adequate means of 
ventilation to achieve this. 

 

  When cleaning cut off the electrical supply at all times. Never use liquid or aerosol detergent, 

use a soft damp cloth instead. 

 

  Never insert anything metallic into the enclosure opening. This may create an electric shock 

hazard or hazard from rotating fan blades. 

 

  To avoid electric shock, never touch the inside of the system.  There are no user adjustable 

components inside, only a qualified technician should open the system’s case. 

 

  Fins on the rear system enclosure are to allow for cooling. To prevent overheating, these fins 

should not be blocked or covered. 

 

  If the system does not operate normally – in particular, if there are any unusual sounds or smells 

coming from it – disconnect it immediately. 

 

  Do not put pressure on the LCD panel screen because it is very fragile. 

 

  Always handle the system with care when moving it. 

 

  Take care that the system is disposed of correctly at the end of its life. If in doubt refer to your 

local ordinances or regulations for proper disposal. 
 

  A socket-outlet shall be installed near the equipment and shall be easily accessible. 

 

Cleaning the LCD monitor 

 
To clean the LCD panel: 

  Wipe the screen gently with a clean lens brush made of camel hair, or a soft, clean, lint free 

cloth. This is to remove dust and other particles without scratching the LCD panel. 

  If it is still not clean, then wipe with a damp lint free cloth and blow on it to dry. 

  Desirable cleaners are water, IPA (Isopropyl Alcohol) or Hexane.  

 
Do not clean the panel with a Ketone type material (e.g. Acetone), or Ethyl alcohol, Toluene, Ethyl 
acid, Methyl chloride. These may permanently damage the polarizer due to chemical reaction. 
 
Do not apply pressure to the LCD panel. 

 
 

Summary of Contents for VTPC150VHBR

Page 1: ...or Demanding Applications VARTECH S Y S T E M S I N C 15 0 Enclosed VESA Mount PC Model VTPC150VHBR VTPC150VSHBR User s Guide Read these instructions completely before attempting to operate your new VESA Mount PC ...

Page 2: ...19 0 Enclosed VESA Mount PC 486 0013 00 03 2 Revision History Date Rev No Summary Page 01 07 09 00 First Issue 07 10 09 02 Revised Product Drawing Detail A 7 08 05 09 03 Added VDC VSDC versions 5 6 ...

Page 3: ...prevent overheating these fins should not be blocked or covered If the system does not operate normally in particular if there are any unusual sounds or smells coming from it disconnect it immediately Do not put pressure on the LCD panel screen because it is very fragile Always handle the system with care when moving it Take care that the system is disposed of correctly at the end of its life If i...

Page 4: ...dard Computer System Processor Intel Atom N270 1 6 GHz Processor with a 533 Mhz FSB System Memory DDR2 533 SO DIMM 2 GB system max 2GB BIOS AMI BIOS Hard Drive 500 GB SATA system max 2x SATA Operating System Microsoft XP Professional SP3 Expansion Slots 1x PCI Express Mini Card I O Ports 1 Power Connector 1 LAN port 2 LAN Optional 2 RS 232 COM port 2 USB 2 0 ports 1 Audio line out Graphics Intel G...

Page 5: ...Interface Serial Environmental Power Input 100 240 VAC 1 5A 50 60 Hz Power Consumption Standard Dual Core 75W 68W Temperature Operational 14 F to 113 F 10 C to 45 C Storage 4 F to 149 F 20 C to 65 C Dual Core Processor 14 F to 104 F 10 C to 40 C Humidity Operational 0 to 90 RH NC Storage 0 to 95 RH NC Installation of Your Enclosed VESA Mount PC Packaged with each carton will be 1 VTPC150VHBR or VT...

Page 6: ...ed with the unit 3 Tighten all mounting hardware to a torque of 15 inch pounds ATTENTION Mounting hardware must be tightened to a torque of 15 inch pounds to provide a proper panel mount and avoid potential damage Vartech Systems assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure due to improper installation 4 Attach the power and system c...

Page 7: ...baud rate from 300 to 19 2 baud The system is supplied with two 10ft cable with a 9 pin D shell connector is located on the rear lower panel of the system Ethernet Connections LAN The Enclosed VESA PC is supplied with integrated Ethernet The interface will support 10 100 1000 BaseT connection to a local area network LAN The system is supplied with a 10ft cable with an RJ 45 female connector locate...

Page 8: ...be properly shut down and power turned off when the Enclosed VESA Mount PC is not in use LCD Monitor Warm up Time All LCD monitors need time to become thermally stable the first time you turn them on Therefore to achieve more accurate adjustments for parameters allow the LCD monitor to warm be on for at least 20 minutes before making any screen adjustments Maintenance The Enclosed VESA Mount PC is...