Caution! The incoming power switch must be set correctly before powering the computer. 
Failure to do so may cause serious damage to the equipment and or injury to personnel. 

 

 

4)  Connect the ground wire to the ground stud in the bottom of the enclosure as shown in Figure 2.  A 

wire runs from this stud to the terminal block. This wire must remain connected. 

 
5)  Connect 110/220 VAC, 50/60 Hz power to the Mains Power terminal block inside the enclosure. Make 

sure that the “L1/L,” “L2/N” and “GROUND” leads are correctly connected to the marked positions. 

 

 

Caution! For safe system operation, the neutral and ground wire must be properly 
connected. 

 

6)  Secure the conduit connectors as recommended by the manufacturer. 
 
7)  Do not cover the rear extrusion of the unit with any material that will hamper the free air exchange 

needed to maintain the cooling system. 

 
 
 

Summary of Contents for VT170ESC

Page 1: ... All In One Computer User s Guide Read these instructions completely before attempting to operate your new Color Display USER MANUAL Solutions for Demanding Applications Industrial CRT and Flat Panel Displays VARTECH S Y S T E M S I N C ...

Page 2: ...VT170 190ESC 2 150 113 Model Number VT170ESC ______ 17 display VT190ESC ______ 19 display Serial Number ________________________________ Copyright 2006 All rights reserved January 2006 ...

Page 3: ...4 Electrical Protection 4 Technical Specifications 5 Fans 5 Environmental 5 Mechanical 5 CHAPTER 2 INSTALLATION 6 Installation Requirements 6 Rack or Cabinet Mount 6 Outdoor Installation 7 Installation Hardware 7 Wiring Requirements 8 Connecting Power 8 CHAPTER 3 MAINTENANCE AND REPAIR 11 Cleaning 11 Preventive Maintenance 11 Check Every Three Months 11 APPENDIX A SUPPORT INFORMATION 12 VarTech Sy...

Page 4: ...notify the local carrier and submit a report to VarTech Systems Inc Remove the packing slip and confirm that all ordered components are present Make sure no spare parts or accessories are discarded with the packing material Please do not return equipment to VarTech Systems without a Return Material Authorization RMA number See Appendix A Overview of System Features NEMA 4x Enclosure Systems are bu...

Page 5: ...Operating 0 C to 50 C Storage 20 C to 65 C Humidity Per IEC 68 2 1 2 3 14 Operating 10 to 95 Storage 5 to 95 Operation at 50 C is possible but may shorten component life Operation at 35 C or lower is recommended If prolonged operation at over 35 C is needed a high temperature option is available Mechanical Material Brushed 316L stainless steel door ring extruded aluminum back frame heat exchanger ...

Page 6: ...imes the unit weight TS 500 66 lbs The enclosure must have complete vertical and lateral support It is recommended that metal framing channels and fittings such as Unistrut or Superstrut be used Caution Systems must be installed in a location capable of supporting four times the unit weight see above Failure to choose a suitable structure could cause the unit to become a hazard to personnel and eq...

Page 7: ... be avoided Solar radiation will directly heat the heat exchanger panels for most of the day 4 For southern latitudes facing south is the preferred orientation Caution To avoid equipment damage any system installed outdoors must be provided with shielding from direct solar radiation If shelter is not available you must install the optional sunshield Installation Hardware Warning systems must be in...

Page 8: ...he bottom panel of the enclosure for routing power and signal lines or other NEMA 4 IP66 rated conduit connectors The standard configuration includes two 1 inch trade size liquid tight conduit fittings Other configurations including sealing fittings and bulkhead connectors are available It is strongly recommended that installations include a flexible section of conduit for example three feet of co...

Page 9: ...ices or your local code when wiring and connecting this unit to a power source and to electrical sensors or peripheral devices Failure to do so could result in injury or death Only qualified personnel should perform wiring procedures Warning Before proceeding make sure that incoming electrical power has been disconnected and there is no electrical power on the leads you will be connecting After pr...

Page 10: ...erminal block This wire must remain connected 5 Connect 110 220 VAC 50 60 Hz power to the Mains Power terminal block inside the enclosure Make sure that the L1 L L2 N and GROUND leads are correctly connected to the marked positions Caution For safe system operation the neutral and ground wire must be properly connected 6 Secure the conduit connectors as recommended by the manufacturer 7 Do not cov...

Page 11: ...at the computer fan is operating b Check that the power supply fan is operating c Verify the heat exchanger fans are operating 2 Verify that all cable connectors are securely fastened 3 Check door seal for nicks breaks or loosened mounting adhesive 4 Verify that all conduit and cable connections are secure 5 Check all cables for nicks frayed or damaged insulation Check closely the area where the w...

Page 12: ...s Limited Warranty VarTech Systems Inc warrants this enclosure against defects in material or workmanship provided the serial number appears on the product and is as originally configured by VarTech If failure of the product has resulted from accident abuse or misapplication VarTech Systems Inc shall have no responsibility under this limited warranty Corporate Headquarters VarTech Systems Inc 1152...