POWX1730
EN
Copyright © 2015 VARO
P a g e
|
8
www.varo.com
8.4
Storage
I mportant! Pull the mains plug out of the socket and ventilate the appliance
and all connected pneumatic tools. Switch off the compressor and make
sure that it is secured in such a way that it cannot be started up again by
any unauthorized person.
Important! Store the compressor only in a dry location which is not
accessible to unauthorized persons. Always store upright, never tilted!
9 TECHNICAL DATA
Type
POWX1730
Rated voltage
230V
Rated frequency
50Hz
Rated Power
1100W / 1,5 pk
Rotation speed
3400 min
-1
Rated Pressure
8 bar / 116PSI
Tank capacity
24 l
Air debit (capacity)
180 l/min
Weight
20 kg
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
77 dB(A)
Acoustic power level LwA
97 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
CAUSE
REMEDY
The compressor
does not start
1. No supply voltage
1. Check the supply voltage, the power
plug and the socket-outlet.
2. Insufficient supply
voltage
2. Make sure that the extension cable is
not too long. Use an extension cable with
large enough wires.
3. Outside temperature
is too low
3. Never operate with an outside
temperature of below +5°C.
4. Motor is overheated
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is
no pressure
1. Leak in the non-return
valve
1. Replace the non-return valve
2. The seals are
damaged.
2. Check the seals and have any
damaged seals replaced by a service
center
3. The drainage screw
3. Tighten the screw by hand. Check the