VARO PowerPlus POW403 Manual Download Page 5

 

POW403 

EN

 

Copyright © 2015 VARO 

P a g e

 | 

5

 

www.varo.com 

8  TECHNICAL DATA 

Power rating 

230-240V~50Hz 

Mains voltage 

180W 

Vibration 

10000min

-1

 

9  NOISE 

Noise emission values measured according to relevant standard. (K=3) 

Acoustic pressure level LpA 

78 dB(A) 

Acoustic power level LwA 

89 dB(A) 

ATTENTION! Wear hearing protection when sound pressure is over 85 
dB(A). 

aw (Vibration): 

2.6 m/s² 

K = 1.5 m/s² 

10 CLEANING AND MAINTENANCE 

 

The machine does not require any special maintenance. 

 

For safe and efficient working, always keep the machine and the ventilation slots clean. 

 

Always be sure that the tool is switched off and unplugged before carrying out any work on 
the tool. 

11 WARRANTY 

 

This product is warranted as provided by law for a 24 -month period effective from the 
date of purchase by the first user. 

 

This warranty covers all material or production flaws excluding : batteries, chargers, 
defective parts subject to normal wear & tear such as bearings, brushes, cables, and 
plugs, or accessories such as drills, drill bits, saw blades, etc. ; damage or defects 
resulting from maltreatment, accidents or alterations; nor the cost of transportation. 

 

Damage and/or defects resulting from inappropriate use also do not fall under the 
warranty provisions. 

 

We also disclaim all liability for any bodily injury resulting from inappropriate use of the 
tool. 

 

Repairs may only be carried out by an authorised customer service centre for Powerplus 
tools. 

 

You can always obtain more information at the number 00 32 3 292 92 90. 

 

Any transportation costs shall always be borne by the customer, unless agreed otherwise 
in writing. 

 

At the same time, no claim can be made on the warranty if the damage of the device is the 
result of negligent maintenance or overload. 

 

Definitely excluded from the warranty is damage resulting from fluid permeation, excessive 
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate 
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not 
following the instructions given in the manual), inexpert assembly, lightning strike, 
erroneus net voltage. This list is not exhaustive. 

 

Acceptance of claims under warranty can never lead to the prolongation of the warranty 
period nor commencement of a new warranty period in case of a device replacement. 

 

Devices or parts which are replaced under the warranty  therefore remain the property of 
Varo NV. 

 

 We reserve the right to reject a claim whenever the purchase cannot be verified or when it 
is clear that the product has not been properly maintained. (Clean ventilation slots, carbon 
brushes serviced regularly, etc.). 

Summary of Contents for PowerPlus POW403

Page 1: ...king area 3 5 2 Electrical safety 3 5 3 Personal safety 3 5 4 Power tool use and care 4 5 5 Service 4 6 ADDITIONAL SAFETY INSTRUCTIONS 4 7 OPERATING INSTRUCTIONS 4 7 1 Switching On off 4 7 2 Attaching the sandpaper 4 7 3 Dust extractor connection 4 8 TECHNICAL DATA 5 9 NOISE 5 10 CLEANING AND MAINTENANCE 5 11 WARRANTY 5 12 ENVIRONMENT 6 13 DECLARATION OF CONFORMITY 6 ...

Page 2: ...ve remaining packaging and packing inserts if included Check that the package contents are complete Check the appliance the power cord the power plug and all accessories for transportation damage Keep the packaging materials as far as possible until the end of the warranty period Then take it to your local waste disposal system WARNING Packaging materials are not toys Children must not play with p...

Page 3: ...l electric shock Do not damage the cord Never use the cord for carrying pulling or unplugging the power tool Keep the cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of a lethal electric shock When operating a power tool outdoors use an extension cable suitable for outdoor use Using a cord suitable for outdoor use reduces the risk of a lethal electr...

Page 4: ...e operation of the power tool If it is damaged the power tool must be repaired Many accidents are caused by using poorly maintained power tools Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to jam and are easier to control Use the power tool accessories and cutting tools etc in accordance with these instructions and in the manner inte...

Page 5: ...r the warranty provisions We also disclaim all liability for any bodily injury resulting from inappropriate use of the tool Repairs may only be carried out by an authorised customer service centre for Powerplus tools You can always obtain more information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same ti...

Page 6: ...ONFORMITY VARO N V Joseph Van Instraat 9 BE2500 Lier BELGIUM declares that Product TRIANGULAR SANDER Trade mark POWERplus Model POW403 is in conformity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unauthorized modification of the apparatus voids this declaration European Directives ...

Reviews: