12 TROUBLESHOOTING 

Incidents 

Causes 

Remedies 

Pump does not start 

 

No mains supply 

 

Floater does not switch 

 

Check mains supply 

 

Bring floater in a higher 
position 

No flow 

 

Inlet sieve is clogged 

 

Pressure hose in bent 

 

Clean inlet sieve water jet 

 

Reset hose 

Pump does not switch off 

 

Floater cannot sink down 

 

Place pump properly on shaft 
ground 

Insufficient flow 

 

Inlet sieve is clogged 

 

Reduced pumping capacity 
by dirty and abrasive water 

 

Clean inlet sieve 

 

Clean pump and replace 
worn-out parts 

Pump switches off  after 
short operating period 

 

Thermal cutout stops 
pumps due to dirty water 

 

Water too hot. Thermal-
cutout stops pump 

 

Remove mains plug. Clean 
pump and shaft 

 

Make sure that a water tem-
perature of max. 35°C is not 
exceed 

13 STORAGE 

 

Thoroughly clean the whole machine and its accessories. 

 

Store it out of the reach of children, in a stable and secure position, in a cool and dry 
place, avoid too high and too low temperatures. 

 

Protect it from exposure to direct sunlight. Keep it in the dark, if possible. 

 

Don’t keep it in plastic bags to avoid humidity build-up. 

 

 

Summary of Contents for POWERPLUS GARDENPRO POWXG9504

Page 1: ...BEFORE START UP NOTE THE FOLLOWING 3 7 INSTALLATION 3 8 SETTING TO WORK 4 8 1 Venting the pump before use 4 8 2 Setting the ON OFF operating point 4 9 CLEANING AND MAINTENANCE 4 9 1 Maintenance guidel...

Page 2: ...e plug 5 floating switch 6 carrying handle 7 cable clamp 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the p...

Page 3: ...cted from moisture If there is danger of flooding the electrical connections must be taken to higher ground Circulation of aggressive fluids as well as the circulation of abrasive materials must be av...

Page 4: ...15 seconds before the pump to start 8 2 Setting the ON OFF operating point The ON and OFF operating point of the float switch can be set by adjusting the float switch in its latching holder Before yo...

Page 5: ...with clear water 9 2 Cleaning the impeller If excessive deposits collect in the pump case you must dismantle the bottom part of the pump as follows 1 Remove the intake cage from the pump case 2 Clean...

Page 6: ...acity by dirty and abrasive water Clean inlet sieve Clean pump and replace worn out parts Pump switches off after short operating period Thermal cutout stops pumps due to dirty water Water too hot The...

Page 7: ...damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fluid permeation excessive dust penetration intentional damage on...

Page 8: ...dards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 35 EU 2014 30 EU Eu...

Reviews: