VÄRMEBARONEN EP 31 300
Window two
---- îîîîîîîî ----
ĮTIME BLOCK DISABLED
PEC MAX LIMIT: 200
O-TEMP function: Rel
O-TEMP level: +10°C
--------------------
---- ïïïïïïïï ----
---- îîîîîîîî ----
ĮTIME BLOCK DISABLED
PEC MAX limit 200
O-TEMP function Rel
O-TEMP level +10°C
Ext TEMP. ADJ. NO
---- ïïïïïïïï ----
ĮTIME BLOCK DISABLED
Limits power connection after a power cut which has lasted
longer than three minutes. See 'Delayed power connection'
under 'Operation and maintenance', options:
Disabled: no function.
Enabled: delayed power connection.
ĮPEC MAX limit 200
Limit value, 0-500 quality factor, for PEC function alarm.
ĮO-TEMP function Rel
ĮO-TEMP level +10°C
Over temperature function:
Rel: over temperature, 5-15°C, relative to setpoint.
Abs: absolute value for over temperature , 105-106°C,
Temperature level for the over temperature function, range:
5 - 15°C when relative setpoint is selected.
35 - 105°C at absolute temperature.
with UTK
ĮExt TEMP. ADJ. NO
Will the function be used with closing or open contact,
alternative:
No
J2
→
O Open
J2
→
C Closed
Installation menu
Window three
Į ---- îîîîîîîî ----
SINGLE
--------------------
- to MENU SELECTOR!
ĮSINGEL
Information, changes with series operation, option.