background image

CENTRAL VACUUM CLEANER 

O p e r a t i n g   a n d 

I n s t a l l a t i o n   I n s t r u c t i o n s

by

Summary of Contents for CENTRAL VACUUM CLEANER

Page 1: ...CENTRAL VACUUM CLEANER Operating and I nstallation Instructions by ...

Page 2: ...uality product Made in Germany Hygienic cleanliness easy and whisper quiet operation are convincing arguments for choosing this central vacuum system Modern production facilities in Germany selected materials and examined quality are the basis for the 5 year guarantee issued from the original purchase date Enjoy your new home help 2 ...

Page 3: ... they will damage the filter Also do not vacuum any cement dust since the dust hardens with moisture and will clog the filter The central vacuum cleaner is not designed to suck in fluids of any sort Always use the central vacuum cleaner with a filter Otherwise the motors may be damaged The dirt container must be emptied regularly Dust bags are enclosed to prevent dust from leaking out when emptyin...

Page 4: ...or the extracted air side of the pipe installation please use the following dimensions Exhaust pipe length up to 3 m use 2 inch adhesive pipe Ø 50 mm Exhaust pipe length 3 m up to 8 m use pipe Ø 70 mm Exhaust pipe length longer than 8 m use pipe Ø 100 mm Generally avoid using an exhaust pipe longer than 3 m If the exhaust pipe needs to be any longer please consider an alternative location for your...

Page 5: ... us know the extent of damage date of purchase and serial number You will find the serial number on the model plate on the side of the central vacuum cleaner or on the test certificate on page 19 under Technical Data For the wall mount please use the enclosed drilling template The wall mount should be at least 1 m up to 1 4 mm above the ground 5 3 In the material bag you will find a seal for the w...

Page 6: ... the central vacuum cleaner Place rubber sleeve and the remaining two hose clamps over the suction pipe and secure the rubber sleeve for one via the stub and for another via the suction pipe The pipe section should have a length of at least 6 cm before installing an elbow or tee This enables a future withdrawal of the unit 7 Connect the 12 24 V control line from the vacuum line to the 24 V control...

Page 7: ...y for use after it has been plugged in The appliance is switched on when a standard hose is inserted into an inlet valve Turning on The appliance can be switched off by removing the hose from the inlet valve Turning off STARTING THE APPLIANCE WITH THE STANDARD HOSE ...

Page 8: ...hat it fits into the grove of the inlet valve Turning on To use the remote control hose the roll bar on the handle must be switched into the ON position When using the remote control hose the appliance is shut off when the roll bar on the handle is switched into the position OFF Turning off After the appliance is shut off from the handle you may disconnect the hose from the inlet valve STARTING TH...

Page 9: ...OFF switch located on the handle The appliance will then run with 100 suction power The central vacuum cleaner is shut off by using the ON OFF switch located on the handle of the hose Turning off After the appliance is shut off from the handle you may disconnect the hose from the inlet valve The central vacuum cleaner is always on stand by The reset button on the appliance is to switch off the car...

Page 10: ...I II or III on the handle to turn the central vacuum cleaner on These buttons allow you to set and vary through all three vacuum power levels Press the 0 button on the handle to turn the central vacuum cleaner off Turning off After the appliance is shut off from the handle you may disconnect the hose from the inlet valve STARTING THE APPLIANCE WITH THE RADIO CONTROL HOSE ...

Page 11: ...ed in Indicator light is lit up Keep the reset button pushed down until the indicator light is lit green Then press any button on the Radio Control hose and then let release the reset button Please repeat these instructions for each Radio Control hose and vac pan TEACH IN PROCESS RADIO CONTROL SYSTEM ...

Page 12: ...ter emptying out the dirt container and inserting a new dust bag press down the reset button on the appliance for 2 seconds The light on the handle will not be light up the next time you use the system Orange light Filter symbol The filter is dirty and should be washed out with water Please follow directions listed on page 15 After the filter is cleaned and dry re insert the filter Then press down...

Page 13: ...the central vacuum cleaner The central vacuum cleaner is equipped with long life electric motors All bearings have permanent lubrication The carbon brushes have a service life of approximately 750 operating hours According to our experience your central vacuum cleaner will operate up to 6 10 years The motors then automatically turn off After the brushes have been exchanged by authorized personnel ...

Page 14: ...ne Volume Maximizer per dust bag Insert the Volume Maximizer as shown above Make sure that the dust bag is fitted tightly against the dirt container 7 8 7 Hook the right and left fasteners back into place 8 Close the fasteners by pulling them down slowly Make sure the dirt container is pulled tight under the housing so that it has a perfect seal 10 Plug the appliance back in Then press down the re...

Page 15: ...r Only when the filter is completely dry it can be put back into the central vacuum cleaner Damp filters become blocked quickly Please disconnect the power 1 2 1 Remove dirt container as described on page 13 2 Pull an empty dust bag over the edge of the housing Carefully draw the ties together to seal the dust bag tight against the housing to prevent dust or dirt escaping 3 4 3 Loosen the wing and...

Page 16: ...d make sure that the container is pulled tight under the housing see page 13 The central vacuum cleaner is closed and can now be turned back on 8 Plug the appliance back in If you have the VIP model you ll have to re plug in the appliance Then press down the reset button for 2 seconds The appliance is ready for use Pull out the cover into an upwards direction by help of two fingers Insert the new ...

Page 17: ...vice Loose seal between Check the seal on the housing housing and dirt container and clean it Also check the sealing ridge on the dirt container and clean it Re attach dirt container If the seal is damaged notify customer service Central vacuum cleaner Electric plug not in socket Insert plug into socket will not turn on Main fuse has blown Change fuse If it blows again please notify customer servi...

Page 18: ...on page 15 Reset button was not pressed Please press down the reset button on the appliance for 2 seconds after you have followed all maintenance steps Maintenance symbol is on Carbon brushes are worn off Please notify a Service VIP only technical problems with the technician appliance 18 Please disconnect all power from the central vacuum cleaner before cleaning the unit or attempting any care an...

Page 19: ...on card You will then receive a new or repaired central vacuum cleaner The guarantee only covers faults in material and manufacture Excluded are normal wear and tear damages due to incorrect use and effects of damp and other external influences or to the intervention of third parties After the guarantee has expired repairs carried out or repairs not covered by the guarantee are invoiced to you We ...

Page 20: ...ZS VV BA GB 1302 TEC HNIC AL DATA All technical data are factory specifications Technical data are subject to change Made in Germany Inspection Certificate ...