Disposal
44
322891 / 396630
V_01/02/2011
GB
If you are unable to eliminate the error yourself, please contact your local OBI market directly.
Please remember that repairs carried out by non-professionals will invalidate your warranty claim
and may cause additional costs.
Disposal
Disposal of the appliance
Appliances which are labelled with the adjacent symbol must not be disposed of in
household waste. You must dispose of such old electrical and electronic equipment sep-
arately.
Please check with your local authority about the possibilities for correct disposal.
Through separate disposal you send old equipment for recycling or for other forms of re-use. You
will thus help to avoid in some cases that damaging material gets into the environment.
Delivery rate too low.
Not enough pressure.
Water shortage?
Ensure sufficient water supply.
Suction pipe not sealed?
Seal suction pipe, tighten
screwed connections.
Suction height too high?
Observe maximal suction
height (
).
Suction height must be de-
ducted from the conveyance
height.
Filter blocked or soiled?
Clean or replace filter.
Check valve blocked?
Clean or replace valve.
Water leak between motor
and pump, shaft sealing is not
sealed?
Contact your local OBI store.
Pump is blocked or defective? Clean the pump with clean
water and remove the cause
of the contamination.
Air in the pump or suction
pipe?
Fill pump case with water.
For suction pipes with check
valve, fill suction pipe with wa-
ter.
Changed suction conditions in
spring (springs e. g. covered
in sand)?
Check spring and water quali-
ty.
Suction pipe sucked in on the
ground?
Shorten or fasten suction pipe.
Use filter screen with check
valve.
Error/Fault
Cause
Remedy
Gartenpumpe_322891_396630.book Seite 44 Montag, 7. Februar 2011 8:50 08