Page 31
CHAPTER 3 - USER’S GUIDE
MINIMUM RAMPING
Minimum ramping is the lowest that the
ramping function can adjust the main set point
to. This is a security feature.
The minimum ramping setting is adjusted in 0.5
degree increments from a minimum setting of
13.5°F (-9.5°C) to a maximum setting of
105.0°F (41.0°C).
Adjusting the minimum ramping setting:
•
rotate the Selector dial to position (12),
•
rapidly rotate the Adjuster dial back and
forth to enter secondary function mode,
•
rotate the Selector dial to position (9),
•
rotate the Adjuster dial counterclockwise to
decrease the minimum ramping setting,
clockwise to increase it.
The minimum ramping setting is displayed on
the MST-2B.
Limit
NOTE: When the main set point temperature
reaches the minimum ramping limit, the ramping
setting (primary function 9) automatically shuts
off.