TECHNICAL INFORMATION
55
87-900-856-01 (B)
Program Mode
NOTE
The following instructions are applicable to
Turbo-V 250 Controller model 969-9504 only when the
optional "hand held terminal" is installed.
FRONT / REMOTE Selection
•
Press CYCLE NUMBER and PUMP CURRENT
push-buttons together for at least 2 seconds and
the processor enters in a routine where it is
possible to program the controller.
In this routine, the CYCLE push-button is used for
choosing/changing the value or condition; the
PUMP CURRENT push-button is used to enter and
confirm the value. At any time it is possible to exit
this routine by pressing the CYCLE and PUMP
CURRENT push-buttons at the same time for at
least 2 seconds. The display shows:
S O F
T
S T
A R T
M O D E
S E L
E C T
I
O N :
X X X
where:
XXX
= YES or NO.
If YES is selected, the Soft Start mode allows the pump
to ramp-up the Normal speed within ten steps. When
NO is selected, the Soft Start mode is deselected and
the ramp-up of the pump will be done within 180
seconds.
The controller is factory set to YES.
NOTE
The Soft Start mode may be deselected/selected only
when the pump is stopped.
•
Press CYCLE NUMBER to select YES or NO
S O F
T
S T
A R T
M O D E
S E L
E C T
I
O N :
Y E S
•
Enter the selection by pressing the PUMP
CURRENT push-button, and the display shows:
F R O N T
/
R E M O T E
S E L E C T
I
O N
:
X X X X X X
where:
XXXXXX
= means the word FRONT or
REMOTE depending on the last selection.
The controller is factory-set for FRONT panel
operation.
•
Choose the desired selection by pressing the
CYCLE push-button:
F R O N T
/
R E M O T E
S E L E C T
I
O N
:
F R O N T