QUICK START GUIDE

 

WWW.VA R I - L I T E .CO M

CHANNEL REQUIREMENTS

DMX512 CHANNELS

16-Bit Mode (default)

16

**DMX terminator required for last fixture on DMX line.

Data In

Termination**

Data Thru

AC In

AC In

AC In

Data Thru

DESCRIPTION

MENU DISPLAY

23 Channels

WARNING

:  It is the responsibility of the user to adequately protect supply source with a correct size and 

type circuit breaker and not overload circuits. 

AVERTISSEMENT

: Il est de la responsibilité de l’utilisateur de 

protéger adéquatement la source d’alimentation avec une taille correcte et le disjoncteur de type et surchargez 
pas les circuits.* 

TABLE 1.    CURRENT VS. VOLTAGE (1500W LAMP*) 

AC VOLTAGE 

@60HZ

TOTAL LUMINAIRE CURRENT 

(MOTOR + LAMP CURRENT

200V  

10.5A

210V

10.1A  

220V

9.7A  

230V

9.3A  

240V

8.9A

NOTE

:  *1500W Philips MSR Gold FastFit lamp (rated for 1200-1600W operation) running at 1500W. 

WARNING

:  It is not recommended to power any Vari-Lite luminaire from a dimmer - even in ‘NONDIM’ 

mode. Dimmer and non-dim modules are not suitable sources of power because their output modifi es the AC 
wave form. This may work for a short time, but will eventually result in power problems, luminaire mis-operation 
and/or failure and may void the luminaire’s warranty. 

CONNECTING DATA AND POWER 

A maximum of 32 luminaires may be connected in any one DMX data link. 

NOTE

:  This maximum limit applies to the luminaire “daisy chain” only.  Your system or console may require 

fewer luminaires on a single data link path.  Consult your console documentation for more information. 

To connect power and data: 

Step 1. 

Connect data cable from console to fi rst luminaire in chain at DATA IN connector. 

Step 2. 

If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of 
remaining luminaires in link. 

Step 3. 

At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and 
other devices on the same DMX chain may not function properly without termination.)

 

FIGURE 2.  DATA LINK 

Step 4. 

Connect AC Input Cable connector to power input source. 

Step 5. 

Dress AC input and data cables and secure them so that they will not interfere with luminaire head 
and yoke movement. 

Summary of Contents for VL6500 WASH

Page 1: ...VL6500 WASH QUICK START GUIDE ...

Page 2: ...ollowing optional and or replacement items can be ordered directly from your Authorized Vari Lite Dealer When ordering please order by the Vari Lite part number VARI LITE PART NO ACCESSORY PCT1BE AC Input Cable Neutrik powerCON True1 with Bare End no connector 1 Meter PC1GTL208 AC Input Cable Neutrik powerCON True1 with Twist Lock Male 250V 1 Meter PCT1GP AC Input Cable Neutrik powerCON True1 with...

Page 3: ... CONNECTION green yellow AC ground blue AC neutral brown AC line International Harmonized Standard WARNING DO NOT connect to three phase service in countries with 240 volt power For single phase power at 208 240 V RMS CONNECTION PIN AC neutral X AC line Y Ground earth G For three phase power at 208 V RMS CONNECTION PIN Phase 1 X Phase 2 Y Ground earth G WARNING It is not recommended to power any V...

Page 4: ...t suitable sources of power because their output modifies the AC wave form This may work for a short time but will eventually result in power problems luminaire mis operation and or failure and may void the luminaire s warranty CONNECTING DATA AND POWER A maximum of 32 luminaires may be connected in any one DMX data link NOTE This maximum limit applies to the luminaire daisy chain only Your system ...

Page 5: ...ed menu item is reached press the desired Menu Button to display the menu options and to navigate and configure the menu options as required To navigate and access menu settings selections Step 1 Make sure unit is powered and turned on Step 2 Press ESC to access menu categories Step 3 Use four Arrow buttons to navigate through the various options and settings Step 4 Once menu item is reached press ...

Page 6: ...re operational information of the luminaire The Status Bar contains the following information LAMP indicates current lamp state ON or OFF SHDN indicates shutdown time in hours NO indicates NO shutdown time ERRORS Displays a number indicating the total amount of current errors When errors are present messages will appear in Red text When no errors are present NO will display ADDR Displays the curre...

Page 7: ...gerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended f...

Page 8: ...oronation Road Park Royal London NW10 7QP United Kingdom Tel 44 020 8965 3209 OCEANIA 14H Vega Place Rosedale Auckland 0632 New Zealand Tel 64 9 481 0100 VL6500 WASH Quick Start Guide Document no Version date June 6 2019 2019 Signify Holding All rights reserved All trademarks are owned by Signify Holding or their respective owners The information pro vided herein is subject to change without notic...

Reviews: