+$37(5
(
48,30(17
'
(6&5,37,21
3
5,1&,3/(6
2)
2
3(5$7,21
37
C O N F I D E N T I A L
0 2 . 9 6 3 8 . 0 0 1 0
2 3 - A u g - 9 9
6HULHV'0;6\VWHP'LDJUDP
Note: Complete instructions for controlling VARI*LITE equipment using
a DMX-512 console can be found in the Series 300/DMX Reference Guide
(02.3004.0300).
The typical Series 300 system operated by DMX control contains Modular
Racks with C3 and APS6 power supply modules installed, a DMX control-
ler, Smart Repeater units, Smart Repeater Plus units, and VL5, VL6, and
VL7 luminaires and VLM mirrors. Series 300 data, 24Vdc, and lamp
power are provided by repeater units to Series 300 luminaires via lamp
cables. Dimming power for VL5/VL5B luminaires is provided by C3
power supply modules, which require the use of an SPC-36 SixPack con-
troller. Arc power for VL5Arc/VL6/VL7 luminaires is provided by APS6
power supply modules. The SPC-36 controller is optional for controlling
APS6 modules.
DMX Console
Splitter or
Opto Isolator
AC Line
Disconnect
Smart Repeater Unit
VL5
VL5
VLM
S300 Lamp Cables
House
Service
Mod Rack
w/ SPC-36 Controller
Smart Repeater
Plus Unit
VL7
S300 Lamp Cables
VL7
VL7
2/0 Pigtails
300DMX
DMX
Cable
Data
DMX
Cable
Data
S200
Cable
Lamp
(Power Only)
APS
Trunk
Cable
APS
Trunk
Cable
DMX
Cable
Data
DMX
Cable
Data
(5-Wire)
AC
AC
AC
AC