Power and Data Cabling Requirements
AC Power
The luminaire requires standard AC power distribution from 90-264 VAC, 50/60 Hz in order to power
all internal electronics and motors. It is equipped with a 3-pole Neutrik® PowerCon® locking
connector (with contacts for line, neutral, and premating safety grounds) for the purpose of AC input.
The mating Neutrik PowerCon® connector is supplied, however, you will need to purchase or
construct a cable appropriate for your application.
Figure 2-1: Power Connector
Current vs. Voltage
The following tables provide the luminaire’s current draw at specific voltages. (Currents given are
worst case with all motors sequencing.)
* Does not include lamp power.
** Includes ballast power.
3-Pole Neutrik
Locking Connector
for AC input
Neutrik PowerCon
Connector (supplied)
Table 2-1: VL1000TS/VL1000TI Current vs. Voltage *
Voltage @ 60Hz
Current
115
1.3 A
208
0.75 A
230
0.65 A
Table 2-2: VL1000AS/VL1000AI Current vs. Voltage **
Voltage @ 60Hz
Current
115
7.8 A
208
4.4 A
230
3.8 A
Summary of Contents for VL1000 ERS Luminaire
Page 1: ...VL1000 ERS Luminaire USER S MANUAL...
Page 13: ...FOREWORD 02 9663 0001 G 05 Oct 2007 xi...
Page 14: ...VARI LITE VL1000 ERS LUMINAIRE USER S MANUAL xii 05 Oct 2007 02 9663 0001 G...
Page 18: ...VARI LITE VL1000 ERS LUMINAIRE USER S MANUAL xvi 05 Oct 2007 02 9663 0001 G...
Page 72: ...VARI LITE VL1000 ERS LUMINAIRE USER S MANUAL 54 05 Oct 2007 02 9663 0001 G Notes...
Page 84: ...VARI LITE VL1000 ERS LUMINAIRE USER S MANUAL 66 05 Oct 2007 02 9663 0001 G Notes...
Page 96: ......
Page 97: ......