![VARES Fruit SHARK Original Instructions For Use Download Page 8](http://html1.mh-extra.com/html/vares/fruit-shark/fruit-shark_original-instructions-for-use_3502014008.webp)
Fruit Crushers SHARK Fruit
Instructions for use
8
• If the machine is not in use for any reason, its electrical equipment must be disconnected from
the mains and an off-state must be secured, by disconnecting the plug/socket combination of the
machine’s fl exible cord.
• It is necessary to maintain the safety marks, symbols and signs on the machine in a legible condition.
If they are damaged or have become ineligible, the user is obliged to restore them in accordance with
the original condition (see points 1.1.2 to 1.1.4 of this manual).
IT IS PROHIBITED!
• To connect the machine’s electrical equipment to an electrical network if any protective device has
been removed or damaged (enclosures of the electrical equipment, covers of dangerous mechanical
components).
• To disable safety, protective or locking devices.
• To make any interventions in the machine’s construction or in its electric circuits.
• To insert any tools or objects, except for material intended to be crushed, into the drum while the
machine is running.
• To carry out maintenance, cleaning and repairs if an off-state of the machine’s electric circuits is not
ensured.
4.2 Fire protection
• CAUTION!
Harmful emissions may be generated by burning of plastic components during a fi re, and,
therefore, it is necessary to abide by generally applicable fi re regulations.
• Water must not be used for extinguish a fi re of the electrical equipment. If a water or foam fi re
extinguisher is to be used for putting out the fi re, it is only possible to use it after power supply has
been turned off!
• It is necessary to regularly clean the surface of enclosures of the electrical equipment, especially the
surface of the electric motor, to remove impurities.
4.3 Electrical equipment
• Electrical installation must be carried out according to the requirements of applicable regulations
and technical standards that apply to the device concerned, in particular ČSN EN 60 204-1 ed. 2 and
related regulations.
• The electric circuit of the single-phase socket for connecting the machine to the mains must be
executed according to the requirements of applicable regulations and technical standards that apply
to the device concerned, in particular ČSN 33 2130 ed. 2, ČSN 33 2000-4-41 ed. 2, ČSN 33 20000-5-
51 ed. 2, ČSN 33 2000-5-54 ed. 2 and related regulations.
• The protection of the socket circuit against electric shock must be executed according to the
requirements of ČSN 33 2000-4-41 ed. 2 by automatic disconnection from power supply; the socket
circuit must be fi tted with a residual current device with a trip current of 30 mA, the proper function
of which must be checked on a regular basis.
Caution!
The fl exible cord between the power supply point and the machine must not
lie freely on the ground without protection against mechanical damage! If an
extension cord is used for connecting the machine to the electrical network,
it must be protected against mechanical damage and it must be placed in such
a way that does not interfere in the machine’s working space and it cannot be
a cause of injury – stumble, slipping!