2.6
Jumper Settings
Two sets of jumpers provide the user the selection of the current output ranges and input
voltage ranges. If the optional Varec on-board 110/220 power supply is used, the VAC selection
must be made. The two AC jumpers must both be set to the applied AC voltage, 110 VAC or 220
VAC. For user-supplied DC power, only the current output range needs to be selected.
Figure 2-4: AC Supply Jumper Setting
AC Version (08-06886-1)
110/220 VAC input voltage jumpers
(Setting for 110 VAC shown)
G
N
L
L2
L4
Field Wiring
AC Electrical Connections