background image

 7 

Continual fresh air 

A continual supply of fresh air is required in the room in wich the stove is situated. This can be 
achieved by installing 1-2 vents, whilst also ensurring that these can not be blocked. The quanti-
ty of air used for burning,  

is approx. 16 

m³ / h.

 

 
 

Tertiary air 

Is constantly added air, which 
makes the stove brun even 
cleaner, and lowers the con-
tent of tar and soor in the 
combustion process to an 
absolute minimum. At optimal 
combustion settings, glass 
and combustion chamber will 
be burnt completely clean, 
and the remaining amount of 
ashes will be minimal. 

 
Overheating 

Occors if too much wood is 
placed in the stove or if the 
combustion receives too much 
air. 

Combustion Air 
Throttel  

Turn the Throttel 
towards left for Air 
Inlet.  
 

 

 

Combustion Air 
Throttel  

Turn the Throttel 
towards right for 
closing Air Inlet.  
 
 

 

 

Max hight of Wood 

BE AWARE 

There must not 

be an extractor fan fitted in 
the same room as the stove 
as this can cause the stove 
to emit dangerous fumes 
into the room. 
 
 

 

 

 

 

BE AWARE 

Do not leave the air sliders 
completely open: Operation 
with the air sliders perma-
nently open can cause ex-
cess smoke. The appliance 
must not be operates with 
air controls or dampers door 
left open except as directed 
in the instructions.

 

Summary of Contents for 6701000 Oslo

Page 1: ...1 Installation and User guide Revision 2 Varde Oslo...

Page 2: ...egulations and approval Page 4 Flooring and distance Page 5 Chimney Page 6 Air supply Page 7 Operation Page 8 How to light and stoke a fire Page 9 List of accessories Page 10 Vermiculite Page 11 How t...

Page 3: ...Nominal Output 4 kW Heated area 30 105m2 Efficiency 78 Flue gas data 4 4g sek 245 C ved 20 C 11 pa Combustion chamber H x W x D 264 x 410 x 256mm Flue outlet 12 5 cm Mounting hight top 493cm Distance...

Page 4: ...ction The stove is designed for intermittent combusti on and can be connected to a chimney used by other fireplaces as long as the appropriate rules and regulations are adhered to See the Building Reg...

Page 5: ...ust be accessible Optimal combustion can only be obtained if fresh air is constantly admitted It is important therefore to ensure that this is the case The best way to provide a steady flow of fresh a...

Page 6: ...at a room temperature of 20 C Varde stoves are always fitted with a smoke plate which redirects smoke to make its way to the chimney as effectively as possible This ensures that the heat from the smok...

Page 7: ...ean and the remaining amount of ashes will be minimal Overheating Occors if too much wood is placed in the stove or if the combustion receives too much air Combustion Air Throttel Turn the Throttel to...

Page 8: ...The Air amount can be regulated Handle towards left 3 Maximum Air Inlet Handle towards right 4 Minimum Air Inlet 2 1 3 4 Combustion Air 2 Push the Air Throttel 2 towards left 3 Your Stove is now in ig...

Page 9: ...re in the combustion chamber before opening the door completely Place 2 logs in a cross on top of the embers approx 1 2 kg and close the door again To make sure the wood ignites quickly we recommend b...

Page 10: ...e page 5 Use of fireguard When using the stove in situations where children and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should...

Page 11: ...is a very porous material and should be handled with care When refilling the stove stoke the wood carefully and use a glove Only use original parts from Varde Ovne A S How too replace the Vermiculite...

Page 12: ...the burning of wood Only dry wood with a moisture content of maximum 21 percent and the size to fit into the combustion chamber should be used The burning of moist wood will result in an increased am...

Page 13: ...the dealer where you bought your stove or your chimney sweeper It is especially important to check the stove and the chimney for blockages after a long period of non use The enamelled surface of the s...

Page 14: ...late and make sure there is free pas sage for the smoke The amount of combustion secondary air is insufficient Combustion is too intense Rope seals in the door or the ash pan are no longer tight and n...

Page 15: ...rts at any time should be needed please chech the list below Vermiculit Set Item no XXXX Sealings Item no 1101 Glass Item no 1130503 Handle Item no 11306124 Cast iron Door Item no 1130526 Glass spring...

Page 16: ...act with combustible material and the refore has no minimum thich ness requirement Note The dimensions are the mini mum dimensions unless otherwise stated Note The minimum distance from bottom of stov...

Page 17: ...17 Test certificat Smoke Control DEFRA in England NS 3058 3059...

Page 18: ...18 Test certificat from Teknologisk Institut is scanned and placed here...

Page 19: ...on missing or wrong maintenance etc see instructions earlier Damages caused by external influence of a physical character Cost of transportation in connection with warranty repairs Assembling reassemb...

Page 20: ...20 Kongevej 246 6510 Gram Danmark Tel 45 7482 0003 vardeovne dk...