7
Continual fresh air
A continual supply of fresh air is required in the room in wich the stove is situated. This can be
achieved by installing 1-2 vents, whilst also ensurring that these can not be blocked. The quanti-
ty of air used for burning,
is approx. 16
m³ / h.
Tertiary air
Is constantly added air, which
makes the stove brun even
cleaner, and lowers the con-
tent of tar and soor in the
combustion process to an
absolute minimum. At optimal
combustion settings, glass
and combustion chamber will
be burnt completely clean,
and the remaining amount of
ashes will be minimal.
Overheating
Occors if too much wood is
placed in the stove or if the
combustion receives too much
air.
Combustion Air
Throttel
Turn the Throttel
towards left for Air
Inlet.
Combustion Air
Throttel
Turn the Throttel
towards right for
closing Air Inlet.
Max hight of Wood
BE AWARE
There must not
be an extractor fan fitted in
the same room as the stove
as this can cause the stove
to emit dangerous fumes
into the room.
BE AWARE
Do not leave the air sliders
completely open: Operation
with the air sliders perma-
nently open can cause ex-
cess smoke. The appliance
must not be operates with
air controls or dampers door
left open except as directed
in the instructions.
Summary of Contents for 6701000 Oslo
Page 1: ...1 Installation and User guide Revision 2 Varde Oslo...
Page 17: ...17 Test certificat Smoke Control DEFRA in England NS 3058 3059...
Page 18: ...18 Test certificat from Teknologisk Institut is scanned and placed here...