Vaportek RESTORATOR Use And Operating Instructions Download Page 2

Thank you for purchasing the Restorator by 
Vaportek. This innovative appliance restores areas 
up to 20,000 cubic feet from odor contamination 
quickly, safely and economically. 

With proper care, your Restorator will provide years 
of trouble-free service. Please read this short 
manual carefully before operating your Restorator, 
and keep it for future reference. 

The Restorator is a simple-to-use, portable electric system 
that quickly, safely and effectively neutralizes odors in 
interior spaces up to 20,000 cubic feet. 

As this unit does not have any “fine” output control, it is 
primarily intended for fast odor-neutralizing treatment at 
high intensity. The characteristic neutralizer fragrance, 
therefore, will be very noticeable in operation, as the 
essential oils circulate throughout the treatment area at 
full output from the machine. 

For initial treatment, it is suggested that the #90-5150 
(3X Industrial) or #90-5150-85 (S.O.S./Smoke Odor 
Solution) cartridge be used. The High-Output (#90-4120) 
cartridge may also be used and is available in several 
fragrances for follow-up treatment, if desired. 

Place the unit where air flow at both ends is unblocked, 
preferably in a relatively high location. Locate on a hard, 
stable surface. Be sure the replaceable cartridge is 
properly installed (see instructions below), with the plastic 
cap removed from the cartridge prior to installation. To 
preserve cartridge life, always store with the cap on when 
not in use. 

Turn the unit on and allow it to deliver odor-neutralizing 
dry vapor for a few minutes. In many cases, deodorization 
will be complete in 30-60 minutes. For more severe 
contamination, treatment may take several hours or even 
days. 

Dry vapor output will be affected by humidity and 
temperature, with vapor release significantly reduced in 
excess humidity conditions (90-100%). Normal interior 
conditions allow the unit to work well. Ideal temperature 
range for best dry vapor release is 60

°

-110

°

 F. 

Finished surfaces may be damaged by direct contact with 
cartridge oils. The essential oils used in the membrane are 
non-toxic; however, if the oils should leak, wash affected 
skin, clothes or surfaces with soapy water. 

The Restorator is designed for use only with Vaportek-
approved replacement cartridges. Use of non-approved 
replacement cartridges will void warranty coverage and 
may cause risk of injury. For best results, replace 
cartridge after 270 hours of use.

 

CONTAMINATED HOTEL ROOMS 

— Place the 

Restorator relatively high in the treatment area 
(i.e., on a table/off the floor). Let run 15-30 minutes 
to penetrate all porous surfaces. 

FIRE/SMOKE DAMAGE 

— Close air vents and doors 

in room. Let Restorator run overnight or longer, 
depending on severity of damage. Residual 
deodorizer vapor will dissipate in a few hours after 
treatment and imbedded malodors will be eliminated. 

AUTO/BOAT RESTORATION 

— The Restorator is 

ideal for removing cigarette, food, mustiness and 
other biological odors in cars, recreational vehicles, 
boats, etc. Run in closed treatment area for 15-30 
minutes (light malodor problem) to 2-3 hours or 
more (for severe odor problems). 

ALSO IDEAL FOR REAL ESTATE, CLEANING 

AND CRIME SCENE SERVICES; FACILITIES 

MAINTENANCE; MORTUARIES; MEETING 

ROOMS; AUTO RENTAL AGENCIES; USED CAR 

DEALERS, DETAIL SHOPS...AND COUNTLESS 

OTHER APPLICATIONS WHERE PROBLEM 

ODORS EXIST! 

THANK YOU! 

SOME SUGGESTED USES 

INSTRUCTIONS 

Place cartridge into back of 
machine with open end of 
cartridge inserted first. (If 
substantial oil leakage 
[dripping] is evident, do not 
use. Re-cap and contact 
dealer or Vaportek.) 

Be sure cartridge is 
positioned properly 
in the internal 
cradle, with open 
end resting against 
the black gasket. 

Fig. 1 

Fig. 2

 

Fig. 3

 

Fig. 4

 

Fig. 5

 

Lift off lid and discard clear 
film liner. (Slight wetness 
under cap is normal.) 

To operate, plug cord into 
appropriate power outlet. Always 
unplug Restorator before removing 
cartridge. To prolong cartridge life, 
remove from machine, re-cap and 
store cartridge upright in a cool, dry 
place. The Restorator cord can be 
coiled for storage in the back of the 
rear cover plate. 

When machine is in use, 
the plastic lid can be 
stored at the back end of 
the cartridge inside the 
machine. 

Replace spring-
loaded rear cover 
plate by pressing it 
against the cartridge 
while turning, until it 
locks into place. 

Fig. 6

 

www.johnson-wholesale.com

Reviews: