17.
TROUBLES AND REMEDIES
TROUBLES
CAUSES
REMEDIES
Little drops of water dripping
This condition is normal during
The inconvenience is normally
from the accessories.
the first minutes of operation;
eliminated after a few minutes
condensate will form because
of operation; If the trouble is
of a difference in temperature
still there, clean the boiler.
between the accessories and
steam.
No water/detergent is
No water or detergent is in
Add more water or detergent.
delivered when the pump
the tank (15)
switches both on the
appliance and on the handle
are pressed ..
TROUBLES
CAUSES
REMEDIES
The appliance is not
Power failure.
Ensure there is power.
functioning.
Faulty cable or switches
Contact the Service Centre.
W ater is coming out from the
Recovery tank is too full.
Empty the recovery tank and
body of the machine (air
check the float; clean float as
outlet).
needed.
Suction power has reduced
Clogged or broken hoses,
Clean hoses, tubes or
noticeably
tubes or accessories.
accessories or replace them.
Empty the recover'b tank.
Recovery tank is too full.
Check if machine ody is
secured to the recovery tank
Insufficient adherence to
and check that the clips are
machine body.
fastened.
The motor is running fast
Clogged hoses, tubes or
Clean hoses, tubes or
(highpitched noise).
accessories.
accessories.
Recovery tank is too full.
Empty the recovery tank.
W ater leaking from
Joint seals worn or leaking.
Inspect, clean and lubricate
accessories joints.
seals; replace seals if
necessary.
Accessories not fully
Dirt has deposited in the joints
Clean and lubricate the joints
engaging.
and quick connections.
and quick connections.
No steam is coming out and
Boiler not yet under pressure
W ait a couple of minutes for
suction is not working.
(green light off).
the green light to illuminate. If
the problem is still there,
contact
one of our Service Centres.
Power failure.
Check that ~ower is available;
check that t e plug is properly
connected to the socket.
Appliance plug is not in the
Check that the appliance plug
...
socket.
is properly connected to the
socket in the electric panel.
X. Overfilling probes in recovery tank. W hen the recovery tank is overfilled, the probes (] 3) will
automatically stop the motor. In this case, you need to restart the appliance.
TROUBLES
CAUSES
REMEDIES
Suction is not working.
Recovery tank is full.
Switch off the appliance via
the appliance switches. Empty
the tank, clean the probes (X),
and allow them to dry.
If the problem persists, contact
your Service Centre.
18
I
(l