background image

                                                      SBC-RK35M Boards User’s Manual   

All rights reserved                                                                                                Page 17, Total 18 

5

 

Tips 

  Waste Disposal 

It is recommended to disassemble the device before abandoning it in conformity with local regulations. 

Please ensure that the abandoned batteries are disposed according to local regulations on waste disposal. Do 
not throw batteries into fire (explosive) or put in common waste canister. Products or product packages with 
the sign of “explosive” should not be disposed like household waste but delivered to specialized electrical

electronic waste recycling/disposal center. Proper disposal of this sort of waste helps avoiding harm and 
adverse effect upon surroundings and people’s health. Please contact local organizations or 
recycling/disposal center for more recycling/disposal methods of related products.   

Comply with the following safety tips: 

  Do not use in combustible and explosive environment 

 
Keep away from combustible and explosive environment for fear of danger.   

  Keep away from all energized circuits.   

Operators should not remove enclosure from the device. Only the group or person with factory certification 

is permitted to open the enclosure to adjust and replace the structure and components of the device. Do not 
change components unless the power cord is removed. In some cases, the device may still have residual 
voltage even if the power cord is removed. Therefore, it is a must to remove and fully discharge the device 
before contact so as to avoid injury.   

  Unauthorized changes to this product or its components are prohibited.     

In the aim of avoiding accidents as far as possible, it is not allowed to replace the system or change 

components unless with permission and certification. Please contact the technical department of Vantron or 
local branches for help.   

 

  Pay attention to caution signs.   

Caution signs in this manual remind of possible danger. Please comply with relevant safety tips below each 

sign. Meanwhile, you should strictly conform to all safety tips for operation environment.   

 

  Notice 

Considering that reasonable efforts have been made to assure accuracy of this manual, Vantron assumes 

no responsibility of possible missing contents and information, errors in contents, citations, examples, and 
source programs.   

Vantron reserves the right to make necessary changes to this manual without prior notice. No part of this 

manual may be reprinted or publicly released in forms of photocopy, tape, broadcast, e-document, etc.

 

Summary of Contents for SBC-RK35M

Page 1: ...SBC RK35M Boards User s Manual SBC RK35M User s Manual Hardware Chengdu Vantron Technology Ltd Co ...

Page 2: ...SBC RK35M Boards User s Manual All rights reserved Page 2 Total 18 Revision record Date Version Change Description 2017 12 25 1 0 Initial Version 2018 03 23 2 0 Revise ...

Page 3: ...S JUMPERS LEDS 11 4 2 1 Reset button 11 4 2 2 B1 RTC Battery 11 4 3 CONNECTORS DESCRIPTION 11 4 3 1 J2 MINI PCIE connector 12 4 3 2 J17 SIM card slot 12 4 3 3 J4 I2C port 12 4 3 4 J5 Debug port 12 4 3 5 J7 Optional backlight control port 12 4 3 6 J9 Power IN port 12 4 3 7 J10 RF antenna for WiFi BT 12 4 3 8 J11 Expand IO s ports 12 4 3 9 J12 RS232 422 port 13 4 3 10 J13 USB HUB ports 13 4 3 11 J14...

Page 4: ...ormation Vantron Technology Vantron E mail sales vantrontech com The trademarks and registered trademarks in this manual are properties of their respective owners No part of this manual may be copied reproduced translated or sold No changes or other purposes are permitted without the prior written consent of Vantron Vantron reserves the right of all publicly released copies of this manual 1 2 Note...

Page 5: ...ing Do not insert other items into the slot if any of this device Keep the ventilation slot ventilated for cooling System fault may arise if other items are inserted into this device Installation ensure correct installation according to instructions from the manufacturer with recommended installation tools Ensure ventilation and smoothness according to relevant ventilation standard 1 8 Safety Inst...

Page 6: ...rgent Clean with a damp cloth Do not try cleaning exposed electronic components unless with a dust collector Support for special fault Power off and contact technical support personnel of Vantron in case of the following faults The device is damaged The temperature is excessively high Fault is still not solved after the operation according to the manual ...

Page 7: ...t error free development process strong fundamentals in technology sufficient in human resources and on time delivery will guarantee the success in your project development Based on idea of Application Ready products and services our embedded computers have embedded basic operation system which includes the drivers of its interfaces So it is easy to be used by adding your application software only...

Page 8: ...SBC RK35M Boards User s Manual All rights reserved Page 8 Total 18 3 SBC RK35M Hardware Instructions 3 1 Board Diagram ...

Page 9: ...SBC RK35M Boards User s Manual All rights reserved Page 9 Total 18 3 2 Board Assembly Drawing ...

Page 10: ...SBC RK35M Boards User s Manual All rights reserved Page 10 Total 18 3 3 Board Structure ...

Page 11: ... double row connector one side is naming odd number and another side is naming even number Please according to below method to confirm the Pin1 of connector and jumper 1 Usually there is any number and mark at side of connector in main board such as trigonal mark dot and number 1 all indicate the pin1 of connector 2 About the hole connector you can see pin number on the reversed side 3 Download th...

Page 12: ...ug port 3 6mm 3Pole 1Port F RA CMT THR RoHS KBIT PJ 320F Matched debug cable PN YC1083R035 4 3 5 J7 Optional backlight control port 1x4 2 54mm 4A 8 18mmH M RoHS MOLEX 22 23 2041 Pin Name Type Description 1 LCD_BLK P LCD backlight power supply 12V OPT 5V 2 GND P Ground 3 PANEL_BKLTCTL O PWM control 4 PANEL_BKLTEN O Backlight ON OFF control 4 3 6 J9 Power IN port BOX 1X4 SIP 2 54 3A M THR RoHS GLW 4...

Page 13: ...W 4Ω speaker 1x2 2 5mm 3A 7mmH M Vert 25 85 THR RoHS NSXD S2501WV 2P Pin Name Type Description 1 SPK R O 2 SPK R O 3 SPK L O 4 SPK L O 4 3 12 J15 10 100 1000M Ethernet port 10 100 1000 MAG 2LED 1Port SHLD F RA 40 85 THR RoHS UNE U50 02 02 G8 09 A122 B12 4 3 13 J16 UART1 RS232 port DB9 1Port NUT M RA IND THR RoHS MOLEX 48203 6073 4 3 14 J18 J19 HUB USB HOST port 4 3 15 J20 Micro USB port Standard M...

Page 14: ...data LVDSA clock 15 EDP_TX3P LVDS_A_CLK O EDP data LVDSA clock 16 GND P Ground 17 EDPAUXN LVDS_A_D3 O EDP LVDSA data 18 EDPAUXP LVDS_A_D3 O EDP LVDSA data 19 eDP_HPD I EDP detect 20 LVDS_B_D0 O LVDSB data 21 LVDS_B_D0 O LVDSB data 22 GND P Ground 23 LVDS_B_D1 O LVDSB data 24 LVDS_B_D1 O LVDSB data 25 GND P Ground 26 LVDS_B_D2 O LVDSB data 27 LVDS_B_D2 O LVDSB data 28 GND P Ground 29 LVDS_B_CLK O L...

Page 15: ...13 4 3 19 J25 expand Aduio port 2x4 2x2mm 2A 4 7mmH M Vert WDT SMT RoHS NSXD MXD2 4PBXX1X Pin Name Type Description 1 MIC_IN R 2 MIC_IN L 3 MIC_DET 4 HP_DET 5 HP_OUT_R 6 HP_OUT_L 7 CPGNDREF Charge pump filtering 8 GND P Ground 4 3 20 J26 Internal USB port 1x4 2 54mm 4A 8 18mmH M Vert WDT THR RoHS MOLEX 22 23 2041 Pin Name Type Description 1 USBH5_VCC P USB power 2 USBH5 IO USB data 3 USBH5 IO USB ...

Page 16: ...bled or debug platform be sure there hasn t any risk of circuit shortness for the board And make sure the anti static is done well c Debug message view Using COM port on P3 COM1 to view the debug message It will show the boot message In PC side communication hyper terminal or other serial software tools can be used The debug port setting is baud rate 115 200bps NO hardware control no ODD EVEN chec...

Page 17: ...rmitted to open the enclosure to adjust and replace the structure and components of the device Do not change components unless the power cord is removed In some cases the device may still have residual voltage even if the power cord is removed Therefore it is a must to remove and fully discharge the device before contact so as to avoid injury Unauthorized changes to this product or its components ...

Page 18: ...ddress 440 Boulder Court Suite 300 Pleasanton CA 94566 Tel 916 202 7042 Email sales vantrontech com China Office Chengdu Vantron Technology Ltd Address 6rd floor 1st building No 9 3rd WuKe East Street WuHou District Chengdu P R China 610045 Tel 86 28 8512 3930 3931 8515 7572 6320 Email sales vantrontech com cn ...

Reviews: