Vantage Hearth VMH26TNC Owners Manual And Installation Manual Download Page 9

www.fmiproducts.com

113111-01

9

InsTallaTIon

IMPORTANT: 

Vent-free fireplaces add mois

-

ture  to  the  air. Although  this  is  beneficial, 
installing fireplace in rooms without enough 
ventilation air may cause mildew to form from 

too much moisture. See 

Air for Combustion 

and Ventilation, 

page 6.

Note: Your VANTAGE HEARTH fireplace is 

designed to be used in zero clearance instal-
lations. Wall or framing material can be placed 
directly against any exterior surface of your 

fireplace, except where standoff spacers are 

integrally  attached.  If  standoff  spacers  are 
attached  to  your  fireplace,  these  spacers 

can be placed directly against wall or fram

-

ing materials.

Use the dimensions shown for rough openings 

to create the easiest installation (see 

Built-In 

Fireplace Installation

, page 10).

CHECK GAS TYPE

Use only the correct type of gas (natural or 
propane/LP).  If  your  gas  supply  is  not  the 

correct  gas  type,  do  not  install  heater.  Call 
dealer  where  you  bought  heater  for  proper 

type heater.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat

-

ing plate. Field conversion is not 

permitted.

INSTALLATION ITEMS

Before  installing  fireplace,  make  sure  you 
have the items listed below.
•  external regulator - propane/LP only (sup

-

plied by installer)

•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection*
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
*  A shutoff valve with 1/8" NPT tap is an ac

-

ceptable alternative to test gauge connection. 

Purchase the optional equipment shutoff valve 

from your dealer. 

Note: If desired, purchase a four-sided trim 
kit for built-in installations. See Accessories, 
page 29.

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri

-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

 WARNING: A qualified ser

-

vice  person  must  install  fire

-

place. Follow all local codes.

 WARNING: Never install the 

fireplace

•  in a bedroom or a bathroom 

•  in a recreational vehicle

•  where  curtains,  furniture, 

clothing,  or  other  flammable 

objects are less than 36" from 

the front, top, or sides of the 

fireplace

•  as a fireplace insert

•  in high traffic areas

•  in windy or drafty areas

 CAUTION: This fireplace cre

-

ates  warm  air  currents.  These 

currents move heat to wall sur-

faces next to fireplace. Installing 

fireplace  next  to  vinyl  or  cloth 

wall  coverings  or  operating 

fireplace where impurities (such 

as,  but  not  limited  to,  tobacco 

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps, 

etc.) in the air exist, may discolor 

walls or cause odors.

Summary of Contents for VMH26TNC

Page 1: ...switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Page 2: ...ot convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING Thisproductcon tainsand orgenerateschemicals known to the state of Califo...

Page 3: ...of gas indicated on rating plate This appli ance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propa...

Page 4: ...ld cause pilot outage 16 Do not operate fireplace if any log is broken Do not operate fireplace if a log is chipped dime sized or larger 17 To prevent performance problems do not use propane LP fuel t...

Page 5: ...ware packet 4 Check fireplace for any shipping damage If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning to dealer WARNING Always have branch support a...

Page 6: ...ut and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter yo...

Page 7: ...ft ceiling height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 30 000 26 0...

Page 8: ...R COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling...

Page 9: ...codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union sediment trap tee joint pipe wrench A shutoff valve with 1 8 NPT tap is an ac ceptable alter...

Page 10: ...and depth of the fireplace CAUTION If you install the fireplace in a home garage fireplace pilot and burner must be at least 18 above floor locatefireplacewheremoving vehicle will not hit it For conv...

Page 11: ...make all electrical connections 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The flex...

Page 12: ...r is installed install a properly grounded 120 volt three prong electrical outlet at fireplace location if an outlet is not there If possible locate outlet so cabinet mantel will cover it when install...

Page 13: ...r Bracket Mounting Holes Figure 13 Installing Fireplace into Mantel Assembly 4 Slide one end of adjusting plate shim in slot on mitered edge of top trim see Figure 14 5 Slide other end of adjusting pl...

Page 14: ...casing see Figure 17 Plug fan kit into 120 Volt grounded power supply and test operation Installing Blower Assembly CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors c...

Page 15: ...ound in hardware kit into the hole left by supply cord strain relief 4 A licensed electrician must follow the wir ing diagram to connect incoming electri cal supply to fan kit wiring harness see Figur...

Page 16: ...ocal codes Use pipe of 1 2 or greater diameter to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Propane LP Supply Tank External Regulator Figure 21 External...

Page 17: ...e Branch Support Screen Screen Shipping Screw Shoulder Screw Flexible Gas Line CONNECTING Equipment shutoff valve to heater control Installation Items Needed Phillips screwdriver sealant resistant to...

Page 18: ...re Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply pip...

Page 19: ...fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the...

Page 20: ...ireplace screen in place Make sure fire place screen is installed before running fireplace NOTICE Duringinitialoperation of new fireplace burning logs will give off a paper burning smell Orange flame...

Page 21: ...uction installation location room size open air temperatures etc Frequent use of your fireplace will let you determine your own comfort levels MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 unde...

Page 22: ...n in Figure 34 turn fireplace off see To Turn Off Gas to Appliance page 21 see Troubleshooting page 24 Figure 33 Correct Burner Flame Pattern Figure 34 Incorrect Burner Flame Pattern Inspecting Burner...

Page 23: ...lean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting beddi...

Page 24: ...osition 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any metal or t...

Page 25: ...lock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 Hand tighten until snug then tighten 1 4 turn more 6 A Contact local propane LP or natural gas company B Clean OD...

Page 26: ...let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 12 4 Clean...

Page 27: ...ly clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ventilation...

Page 28: ...der Warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model an...

Page 29: ...shed Traditional Design W26GO Oak Finished Georgian Design For all models Mantel features clean classic lines Available in a stained oak or unfinished hardwood ready to stain or paint Complete assembl...