![Vantage Hearth Q-ETS3 Installation Download Page 2](http://html1.mh-extra.com/html/vantage-hearth/q-ets3/q-ets3_installation_3416643002.webp)
This device contains transmitter module:
FCC ID: PII-VSUB075-1
IC: 3505A-VSUB0751
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-
-
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this product not expressly approved by Vantage
Controls could void the user’s authority to operate this product.
Status LED Diagnostic Information
During setup and configuration the Q-ETS3 or STHERR101 LED
will blink at different intervals. The STATUS LED blinks evenly
or flashes 2, 3, 4, 5 or 6 times followed by a pause to indicate
status information.
One Even blink: The Q-ETS3 or STHERR101 is correctly
configured.
Two blinks: Q-ETS3 or STHERR101 is operating correctly but is
not configured.
Three blinks: Q-ETS3 or STHERR101 is not communicating with
the Controller. Verify that station bus wiring conforms to
Vantage guidelines or for STHERR101, verify that the serial
number is correct in the software and is in communication
range with the RadioLink Enabler.
Four blinks: Q-ETS3 or STHERR101 Factory problem. Please
contact the factory.
Five blinks: Q-ETS3 (only) Configuration mode. InFusion or
QLink is ready for configuration button presses (Configuration
the Q-ETS3, WireLink™ above) to associate serial number with
programming.
Six blinks: Q-ETS3 or STHERR101 is not communicating with
the thermostat. The thermostat is not properly wired to the
station or, in the case of the Q-ETS3 only, the thermostat is not
powered.
Off: The Q-ETS3 station is not connected to the station bus,
the Controller is not in place or is not powered. The STHERR101
is not powered.
Fahrenheit / Celsius
In
Design Center
, click on Settings | Project Preferences |
Thermostat and click in the desired box. In
QLink
select
System | Global Parameters
from the menu and select
Display
Temperatures in Fahrenheit
. This choice will determine how the
set points are handled throughout QLink, including displaying
temperatures on LCD stations. To toggle Fahrenheit and
Celsius display on the thermostat, go to
Menu | Temperature |
Units
and select
Imperial
or
Metric
and
Save Changes
(see the
thermostat manual).
Thermostat Status on Touch Screens
In the
Touch Screen Designer
window select the
Status
design tool. Draw a
Status
object on the screen. Right click the
status object and click on
Select Thermostat
to finish
programming. Above steps may vary slightly for different
touch screens and or versions of Vantage software.
Thermostat Reset and Calibrations
Please see the Thermostat owners manual:
Standard Q-ETS3 Thermostat Wiring
39818 / InFusion and QLink Systems