Vantage Hearth Q-ETS3 Installation Download Page 2

This device contains transmitter module: 
FCC ID: PII-VSUB075-1 
IC: 3505A-VSUB0751 
This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions:  (1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that 
may cause undesired operation. 
 
NOTE: This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following measures: 
-- Reorient or relocate the receiving antenna. 
-- Increase the separation between the equipment and receiver. 
-- Connect the equipment into an outlet on a circuit different from that to which the        
receiver is connected. 
-

Consult the dealer or an experienced radio/TV technician for help. 

 
Changes or modifications to this product not expressly approved by Vantage 
Controls could void the user’s authority to operate this product.

 

Status LED Diagnostic Information 
During setup and configuration the Q-ETS3 or STHERR101 LED 
will blink at different intervals. The STATUS LED blinks evenly 
or flashes 2, 3, 4, 5 or 6 times followed by a pause to indicate 
status information. 
One Even blink: The Q-ETS3 or STHERR101 is correctly 
configured. 
Two blinks: Q-ETS3 or STHERR101 is operating correctly but is 
not configured. 
Three blinks: Q-ETS3 or STHERR101 is not communicating with 
the Controller. Verify that station bus wiring conforms to 
Vantage guidelines or for STHERR101, verify that the serial 
number is correct in the software and is in communication 
range with the RadioLink Enabler.  
Four blinks:  Q-ETS3 or STHERR101 Factory problem.  Please 
contact the factory. 
Five blinks:  Q-ETS3 (only) Configuration mode. InFusion or 
QLink is ready for configuration button presses (Configuration 
the Q-ETS3, WireLink™ above) to associate serial number with 
programming.  
Six blinks: Q-ETS3 or STHERR101 is not communicating with 
the thermostat. The thermostat is not properly wired to the 
station or, in the case of the Q-ETS3 only, the thermostat is not 
powered. 

Off: The Q-ETS3 station is not connected to the station bus, 
the Controller is not in place or is not powered. The STHERR101 
is not powered. 
 
Fahrenheit / Celsius 
In 

Design Center

, click on Settings | Project Preferences | 

Thermostat and click in the desired box. In 

QLink

 select 

System  | Global Parameters

 from the menu and select 

Display 

Temperatures in Fahrenheit

. This choice will determine how the 

set points are handled throughout QLink, including displaying 
temperatures on LCD stations. To toggle Fahrenheit and 
Celsius display on the thermostat, go to 

Menu | Temperature | 

Units

 and select 

Imperial

 or 

Metric

 and 

Save Changes

 (see the 

thermostat manual). 
 
Thermostat Status on Touch Screens 

In the 

Touch Screen Designer 

window select the 

 

Status

 

design tool. Draw a 

Status

 object on the screen. Right click the 

status object and click on 

Select Thermostat

 to finish 

programming. Above steps may vary slightly for different 
touch screens and or versions of Vantage software.  
 
Thermostat Reset and Calibrations 
Please see the Thermostat owners manual: 

 
 
 
 
 
 
 
 
Standard Q-ETS3 Thermostat Wiring 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

39818 / InFusion and QLink Systems 

Warranty at: 

http://www.vantagecontrols.com/warranty

©Vantage Controls

Reviews: