www.fmiproducts.com
113110-01K
23
Figure 33 - Control Knob and Ignitor
Button Location (Shown as Supplied - No
Control Options)
O
FF
PIL
OT
LO
IH
AUTO
OFF
ON
ON
Control Knob
Ignitor Button
Flame Adjustment Knob
Selector Switch in
OFF Position
4. Press in and turn control knob clockwise
to the OFF position (see Figure 33).
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, column 1. If you
don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for five (5) seconds
(see Figure 33).
Note: You may be running this fireplace for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or less. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
OPERATION
Continued
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 24.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8, page 23.
9. Slightly push in and turn control knob coun-
terclockwise
to the ON position.
10. Wait one minute and switch selector
switch to the ON position to light burner.
11. Set flame adjustment knob to any level
between HI and LO.
Figure 34 - Propane/LP Gas Pilot
Ignitor
Electrode
Pilot
Burner
Figure 35 - Natural Gas Pilot
Ignitor
Electrode
Pilot Burner
12. To shut off burners only and keep pilot
lit, you can turn control knob clockwise
to PILOT position, use remote
control manual OFF button, or set selector
switch in OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Fireplace will come on automati
-
cally with selector switch in the
ON position.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the
OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote:
Set selector switch in the OFF position to
prevent draining battery.