background image

PART DESCRIPTION

PART NUMBER

Feeder Assembly

ACF-8 Feeder

E023008VTG

REPLACEMENT and OPTIONAL PARTS

Optional Installation Parts

ACF-8 Installation Kit 

P008100 

(25 ft of 5/8" o.d. tubing, four 1/2" npt to tubing connectors and a Vantage 1/2" Eductor)

Flow Meter (0-1.0 gpm) 

P2001206

Vantage 1/2" Solenoid Valve 12V 

P2002201

Replacement Parts

Flow Meter (0-1 gpm)

P2002206

25’ of 5/8” OD Tubing

P2002225

Vantage 1/2" Eductor 

P2001212

Vantage 1/2" Solenoid Valve 12V 

P2002201

Vantage Solenoid Valve Rebuild Kit 

P2001213

INSTALLER SUPPLIED PARTS

Due to the wide variety of installations possible, AllChem Performance Products can not supply all parts and
pieces required for installation.  Some commonly available plumbing parts and supplies may be supplied by the
installer.   The recommended optional installation parts are the ACF-8 Installation kit - P008100 (includes 25 feet
of 5/8" o.d. tubing, four tubing connectors, Vantage 1/2" Eductor) and the 0-1.0 gpm flow meter(P2001206).

If the feeder operation will be controlled by an ORP or Amperometric control system, a solenoid
valve(P2002201) will also be required.

NSF/ANSI Standard 50 compliance requires that a flow meter be installed.

Inlet Flow:

0.1 - 1.0 gpm

Inlet Pressure:

10 - 45 psi

Maximum Output: 

6.2 lbs. of Available Cl

2

per Day (pools)

3.0 lbs. of Available Cl

2

per Day (spas)

Capacity:

8 lbs. of Vantage® Calcium Hypochlorite Tablets

Recommended Pool Size

(US Gallons)

up to 50,000 Gallons

Feeder Height

26”

Feeder Width

10.25”

Feeder Depth

10.25”

Feeder weight (full)

23 lbs.

Feeder weight (empty)

15 lbs.

Tubing

5/8” O.D.

For Pool or Spa Use Only

Operating Specifications

1

Certified to 

NSF/ANSI Standard 50

Summary of Contents for ACF-8

Page 1: ...Installation and Operation Manual ACF 8 Automatic Chlorinating Feeder...

Page 2: ......

Page 3: ...and supplies may be supplied by the installer The recommended optional installation parts are the ACF 8 Installation kit P008100 includes 25 feet of 5 8 o d tubing four tubing connectors Vantage 1 2 E...

Page 4: ...nd rain This feeder should be installed on a flat level surface capable of supporting its weight when full This feeder is designed to operate at an inlet pressure of 10 45 psi The flow rate will be co...

Page 5: ...rculation pump and the feeder should be elevated above the level of the circulation pump This installation method may result in some air being drawn back into the circulation pump and possibly returne...

Page 6: ...he influent flow is greater then the effluent flow and water will overflow out the overflow drain 6 Prior to filling feeder read First Aid Precautionary Statements Directions for Use and Storage and D...

Page 7: ...o Injector 1 2 Feeder Inlet Inlet Ball Valve Pressure Gravity Installation Figure 1 ACF 8 sump surge pit balance tank or collection tank Effluent feed line Return line Flow Meter Solenoid to controlle...

Page 8: ...r Inlet Water Flow From Pool Isolation Valve Check Valve Pool Return Ball Valve 1 2 Venturi w check valve Flow Meter Flow Control Valve optional 1 2 Solenoid to Controller P OOL P UMP F ILTER Modified...

Page 9: ...Feeder Inlet Water Flow From Pool Isolation Valves Pool Return Ball Valve Ball Valve Venturi w check valve Flow Meter Solenoid to controller if applicable H EATER if present P OOL P UMP F ILTER ACF 8...

Page 10: ...1 Overflow to waste 1 2 Feeder Inlet Return line Flow Meter Solenoid to controller if applicable Inlet Ball Valve Outlet Ball Valve Flow Pump strainer Pressure Suction Installation Figure 4 ACF 8...

Page 11: ...5 Refill feeder with appropriate amount of Vantage Calcium Hypochlorite Tablets replace feeder lid plug in solenoid valve if applicable turn on water and adjust flow rate for proper chlorine output 6...

Page 12: ...Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and under no...

Page 13: ...VTGACF8IOM 060507 Copyright 2014 Document Version 01 AllChem Performance Products...

Reviews: