background image

Installation and Operation Manual

ACF-250

Automatic Chlorinating Feeder

Summary of Contents for ACF-250

Page 1: ...Installation and Operation Manual ACF 250 Automatic Chlorinating Feeder...

Page 2: ......

Page 3: ...er P2002202 In Line Strainer P2002203 25 of 5 8 OD Tubing P2002225 Feeder Discharge Assembly discharge valve body discharge fitting and locking bolt P601204 Chlorine Feed Assembly sieve plate legs ove...

Page 4: ...ing 4 Float Valve Body 5 Float Assembly 6 Chemical Feed Solenoid Valve 7 Supply Manifold 8 Inlet Water Solenoid Valve 9 Rinse Nozzle 10 Level Switch Assembly 11 Chemical Tank Lid Chlorine Feed Assembl...

Page 5: ...at an inlet pressure of 10 45 psi The flow rate will be con trolled in the range of 2 0 to 3 5 gpm CONNECTING THE ACF 250 RECOMMENDED INSTALLATION METHODS SIDESTREAM WITH BOOSTER PUMP AND VENTURI see...

Page 6: ...desir able in some applications to install the venturi without the use of a booster pump The sidestream is created by using the pressure differential created across the pools filter and heater The sid...

Page 7: ...uitable piping connections to the suction side of the pools circulation pump It may be necessary to make specific valve adjustments so that the feeder will not be com pletely drained by the suction of...

Page 8: ...Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer 1 2 Feeder Inlet H EATER if present P OOL P UMP B OOSTER P UMP F ILTER denotes PVC piping denotes...

Page 9: ...er Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer Flow Control Valve optional H EATER if present P OOL P UMP F ILTER denotes PVC piping denotes...

Page 10: ...he influent and effluent flow as necessary In some situations it may be desirable to adjust the float valve in the solution tank using the bolt located on the float valve arm For detailed instructions...

Page 11: ...oat assembly and other parts can be damaged with rough handling Use caution when cleaning these parts 4 When all parts have been cleaned the interior of the tubing venturi check valve and venturi can...

Page 12: ...alves to prevent water flow into the feeder Do not reopen valves for at least 2 hours following application of shock or superchlorinating product to prevent contamination of tablets WINTERIZATION OF F...

Page 13: ...peration Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and...

Page 14: ...VTGACF250IOM 060507 Copyright 2007 Document Version 01 AllChem Performance Products LP...

Reviews: