Vansco VMM1615 User Manual Download Page 19

User Guide 

 

Quick Start 

 

3.

 

Select 

Install the software automatically (Recommended)

, and then click 

Next

. If the driver is not detected automatically, you can browse to the folder 

containing the driver (default path C:\Program files\Vansco\USB-DLA). 

4.

 

After installation is finished, click 

Finish

. The USB DLA is now recognized 

and ready to be used.  

See the Parker Vansco USB DLA kit user manual for more detailed instructions. 

 

2.3.  Connect the VMM1615 to a Development 

System 

It is a good idea to connect the VMM1615 to a development system (PC, 
Controller I/O Board, power source, and DLA) to verify your ladder logic 
application. The development system is an ideal environment for creating and 
downloading ladder logic software applications. 

The following shows how to connect the VMM1615 in a development system: 

Controller

DLA

I/O Board

Power

PC

 

Figure 2: Development system connection 

 

To connect the VMM1615 in a development system, do the following: 

Note:

 Before connecting anything in the development system, ensure that the 

power supply is set to a voltage that is less than 32 V DC. 

1.

 

Connect the Controller I/O harness to the VMM1615 connectors. 

2.

 

Connect the Controller I/O harness to the controller I/O board connectors. 

3.

 

Connect the evaluation kit power/CAN harness to the controller I/O board’s 
JP3 connector. 

 

Summary of Contents for VMM1615

Page 1: ...Vansco Multiplexing Module VMM1615 User Guide HY33 5008 IB US UG VMM1615 154200 201309 003...

Page 2: ...is and testing is solely responsible for making the final selection of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the applicat...

Page 3: ...2 1 Install the Data Link Adaptor Driver Software 6 2 3 Connect the VMM1615 to a Development System 7 2 3 1 Power Up the Development System 8 2 4 Create and Download Ladder Logic Applications 9 3 Conn...

Page 4: ...ion Connection 47 6 3 Solid State Relays 49 6 3 1 Solid State Relay Capabilities 49 6 3 2 Solid State Relay Installation Connections 50 6 3 3 Solid State Relay Diagnostics 52 7 Communication 53 7 1 Co...

Page 5: ...User Guide v Contents 10 6 1 Open Collector 72 10 6 2 Connecting a Switch to the VMM1615 73 10 6 3 Voltage 73 10 6 4 Potentiometer Ratiometric 74 11 Startup 77 12 Glossary 79 13 Index 85...

Page 6: ......

Page 7: ...e course of its publication history Release Date Description of Change Rev 003 September 2013 Update to match Product Specification ver 02A Minor editorial changes throughout Rev 002 September 2012 Br...

Page 8: ......

Page 9: ...quipment or degradation of signal When you see these symbols follow the instructions carefully and proceed with caution General safety regulations Work on the hydraulics control electronics may only b...

Page 10: ...system 1 Disconnect the electrical connections between the system and external equipment 2 Disconnect the negative cable from the battery 3 Disconnect the positive cable from the battery 4 Connect th...

Page 11: ...verified Do not start the machine if anyone is near the machine Safety during maintenance and fault diagnosis Before performing any work on the hydraulics control electronics ensure that The machine c...

Page 12: ......

Page 13: ...s than 32V This module is 100 compatible with other Vansco Multiplexing Modules Figure 1 VMM1615 The VMM1615 has 16 inputs and 15 outputs Inputs include programmable gain analog programmable attenuati...

Page 14: ...ting the CAN 2 0B standard The standard protocol supported is SAE J1939 but others could be supported through custom software development The VMM1615 follows the controller module road map which provi...

Page 15: ...s The following symbols are used in the schematic diagrams in this document Symbol Meaning General input General output Frequency input Analog input Frequency sensor Pulse sensor Resistive sensor Gene...

Page 16: ...4 VMM1615 About the VMM1615 Symbol Meaning Pull up resistor Battery Fuse Resistor Ground Chassis ground...

Page 17: ...ials 2 Install the required software tools provided by Parker Vansco 3 Connect the VMM1615 to a development system desktop and power it up 4 Download the ladder logic application software 2 1 Gather R...

Page 18: ...Link Adaptor DLA drivers The DLA acts as the interface between the PC and the VMM1615 Before using the DLA you must install the DLA drivers Parker Vansco Software Tools Parker Vansco provides the VMMS...

Page 19: ...ard power source and DLA to verify your ladder logic application The development system is an ideal environment for creating and downloading ladder logic software applications The following shows how...

Page 20: ...that all controller I O board digital inputs jumpers and dip switches are properly configured for your module type Refer to the Controller I O Board Reference Manual for further details 2 Ensure that...

Reviews: