![VANQ VQ-GLCP Series Manual Download Page 17](http://html1.mh-extra.com/html/vanq/vq-glcp-series/vq-glcp-series_manual_3412363017.webp)
Shenzhen VANQ Technology Co., Ltd
.
VQ-GLCP Series THCMax Bloom Light
17
8.3
Instructions
1、
Operating Instructions
Procedure
Key
Function
Note
①
Press“Cancel”Key
Press the "Cancel" Key four times to unlock
②
Press“Prog”Key
Enter the Timer 1“ON” setting
Note 1
③
Press“Hour”
、
“Min”Key
Set the specific ON time [hour, minute]
④
Press“Week”Key
Set repeat cycle from 15 different “repeat modes”
Note 2
⑤
Press“ON/Auto/OFF”Key
Set the Working Channels ON (CH1 Or CH2 Or Both)
Note 3
⑥
Press“Prog”Key
Enter the Timer 1“OFF” setting
⑦
Press“Hour”
、
“Min”Key
Set the specific OFF time [hour, minute]
⑧
Press“Week”Key
Set repeat cycle from 15 different “repeat modes”
(
Should be
same as Set of “ON”
)
⑨
Press“ON/Auto/OFF”Key
Set the Working Channels OFF (CH1 Or CH2 Or Both)
Note 3
⑩
Repeat Operation
①
-
⑧
Set Timer 2/Timers 3...Timers 16 ON/OFF Time
(
If No
Need,Disable the Timer by setting ON- -/OFF - -
)
Note 4
⑪
Press“Clock”Key
Finish Timers Setting
,
Back to Start-up Screen
⑫
Press“ON/Auto/OFF”Key
Press multiple times to switch working modes (Auto) Timer
Enabled/(ON)Timers Disable With Lamps ON or Timers Disabled
With Lamps OFF
Note 5
Note
:
Note 1
During the operation of the Timer Setting, the timers not work.
Note 2
Press“Week”Key multiple times
,
you can change different repeat modes.
Note 3
Press“ON/Auto/OFF”Key
,
Selet the Working Channels (CH1 Or CH2 Or Both).
Note 4
Press “Cancel” Key To Disable the Timer by setting ON- -/OFF - -(Not 00:00),Press”Cancel”Key
again to enable the Timer.
Inspection
:
Multiple press “Prog” Keys to confirm all setting are correct.
Modification
:
If any timer is wrong, by pressing “prog” Key to locate the wrong timer,press
“Cancel” key to clear the setting, reset the timer following the instruction.
If all correct,Press“Clock”Key,back to Start-up Screen.
Note 5 Timers Enabled
:
Unlock the time switch,press “ON/Auto/OFF”Key multiple times to change
modes, If under “Auto” mode
,
the timers will work normally as setting, if under “ON”mode,both
UV and FR lamps will be on with all timers disabled, if under “OFF” mode,both UV and FR
lamps will be off with all Timers disabled.