background image

V-SIX

120V

25799 Jefferson Ave. Murrieta, CA 92562

  

  

1-800-VANIMAN (826-4626)

  

  

www.vaniman.com

  

 

 

[email protected]

V-SIX 08/20

Page 1

PACKING LIST

 

1 - V-Six Dust Collector

 

1 - Power Cord

 

1 to 3 - Port Caps (dependent on inlet configuration)

ASSEMBLY INSTRUCTIONS

1.  Remove the unit and other parts from the packaging and check against the packing list.
2.  Open the front door of the unit to access the filter compartment cover plate. Remove the four black 

thumb screws and remove the cover plate. Locate the wing nut at the bottom of the cartridge filter 

and check to make sure it has not come loose during shipping. Tighten if necessary. 

3.  The V-Six requires 110 -120V, 15A, at 50/60 Hz. It is designed to only be operated indoors in a dry 

environment, and at an altitude below 300 meters and a temperature below 150⁰F. This unit is a 

Overvoltage Catagory II and Polution Degree II product and should only be used as intended.

4.  Plug the removable power cord into the socket on the back of the unit labeled 

Power Cord

. Plug the 

other end into a standard grounded wall socket. Switch the 

Main Power Disconnect

 switch on the 

back of the unit into the 

ON 

position. Test the unit by turning the 

ON/OFF/REMOTE

 switch on the 

front of the unit to the 

ON

 position.

5.  When required to remove the power cord from the unit, first flip the switch in the front of the unit into 

the 

OFF

 position. Then flip the 

Main Power Disconnect

 switch in the back of the unit into the 

OFF

 

position. Confirm that both swtiches are in the 

OFF

 position, then remove the power cord.

6.  The Air Blast filter cleaner requires compressed air to operate. Connect a 1/4 inch NPT male con

-

nector air fitting to the brass female connector located on the back. 

DO NOT SUPPLY MORE THAN 

100 PSI TO THE UNIT.

7.  The ideal location for the unit is in a well ventilated area, as close as possible to the workstations 

to be served. The unit requires clearance of at least 6 inches on all sides and top for adequate air 

movement to prevent the motor from overheating. 

DO NOT 

fully enclose the unit in a cabinet without 

consulting the manufacturer first.

IMPORTANT SERVICE INFORMATION:

SAVE  SHIPPING  BOX AND  FOAM  FOR  FUTURE 

SERVICE.  SHIPPING WITHOUT PROPER FOAM 

MAY CAUSE DAMAGE TO UNIT

Reviews: