Vaniman SANDSTORM MOBILE Manual Download Page 2

140 N. Brandon

  

  

P.O. Box 74, Fallbrook, CA 92088

  

  

1-800-VANIMAN (826-4626)  

 

  

www.vaniman.com

MOBILE SANDSTORM-I-09/14 Page 1

MOBILE SANDSTORM

PACKING LIST

 

1 - SandStorm Mobile

 

1 - Instructions

 

1 - Additional Quick Disconnect

INSTALLATION & OPERATION

1. Unscrew cap on media storage tank

2. Fill abrasive storage tank to fill line with aluminum oxide micron size specified on tank label. The tank 

will hold up to 4 lbs of media. 

DO NOT OVER FILL

 as clogging may result. 

Part No.

Nozzle Size, Inches (mm)

Color

Recommended Media

Long Lasting Crystal Tips (2 per package)

97902

Medium, .032” (.8mm) 

Blue

25/50 μm Al

2

O

3

97903

Large, .048” (1.2mm)

Black

50/100 μm Al

2

O

3

, 50 μm Glass

97904

Extra Large, .065” (1.6mm)

Red

100-250 μm Al

2

O

3

, 50/100 μm Glass

Precision Tungsten Carbide Tips (1 per package)

97905

Small, .026” (.65mm)

Yellow

25 μm Al

2

O

3

97906

Medium, .036”(.91mm)

Green

50/100 μm Al

2

O

3

, 50 μm Glass

97907

Large, .059” (1.5mm)

Violet

100-250 μm Al

2

O

3

, 50/100 μm Glass

3. Wipe off excess abrasive and screw cap securely back into place. 

Do not over-tighten;  lid will self 

seal when under pressure.

4. Attach your 1/4” ID (inside diameter) hose air supply line to the barbed fitting on the back of the unit, on 

the right of the small valve. Secure hose with a small screw-type clamp.  If necessary remove the fitting 

and replace with the quick disconnect fitting.  

NEVER

 depressurize the system by disconnecting the 

air supply line while under pressure; abrasive will be forced into the foot valve and regulator, causing 

damage.  Before disconnecting the air supply line, turn regulator down (counterclockwise) until the 

pressure gauge reads zero. 

**For more help visit http://www.vaniman.com/air-supply-connections-blasters/**

5. Regulate air pressure by turning the air regulator knob.  Pull knob up to unlock before turning.  Pressure 

will indicate pressure reading.  

DO NOT

 adjust above 100 psi (7 BARS).

6.  Use the foot pedal to start the flow of air and blasting media.  Release the foot pedal to stop the flow.