www.fmiproducts.com
113093-01J
30
SPECIFICATIONS
VINTAGE OAK LOG VARIABLE
MANUALLY-CONTROLLED
VYS18PB
• Rating: 16,000/27,000 Btu/hr
• Gas
Type:
Propane/LP
• Ignition:
Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
VYS18NB
• Rating: 16,000/27,000 Btu/hr
• Gas
Type:
Natural
• Ignition:
Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
VYS24PB
• Rating: 16,000/31,500 Btu/hr
• Gas
Type:
Propane/LP
• Ignition:
Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
VYS24NB
• Rating: 16,000/31,500 Btu/hr
• Gas
Type:
Natural
• Ignition:
Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
GOLDEN OAK LOG REMOTE-
READY MODELS
VYD18PRB
• Rating: 21,000/30,000 Btu/hr
• Gas
Type:
Propane/LP
• Ignition:
Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
VYD18NRB
• Rating: 21,000/30,000 Btu/hr
• Gas
Type:
Natural
• Ignition:
Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
VYD24PRB and VYD30PRB
• Rating: 25,000/39,000 Btu/hr
• Gas
Type:
Propane/LP
• Ignition:
Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
VYD24NRB and VYD30NRB
• Rating: 25,000/39,000 Btu/hr
• Gas
Type:
Natural
• Ignition:
Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas sup-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TECHNICAL SERVICE
You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact FMI PRODUCTS, LLC at 1-866-328-
4537. When calling please have your model
and serial numbers of your heater ready.
You can also visit our web site at
www.fmiproducts.com.