Vanguard VMH26TPB 14 Owner'S Operation And Installation Manual Download Page 10

10

107030

COMPACT CLASSIC HEARTH

®

 FIREPLACE

VMH26TPB

®

INSTALLATION

Continued

Figure 13 - Attaching Brass Trim to
Fireplace

Shoulder Screws

Assembled
Brass Trim

Hole for 3" wood
screw for attaching
fireplace to mantel

Figure 14 - Attaching Wood Base to Floor

9.

Place wood base next to wall at instal-
lation location.

10. Attach wood base to floor with two 1 

3

/

4

"

black screws provided (see Figure 14).
If the floor is concrete use anchor method
(see Attaching Wood Base to Solid Floor,
page 14).

11. Install gas line. See Connecting To Gas

Supply, page 14.

12. Check for leaks. See Checking Gas

Connections, page 16.

13. Place mantel around fireplace. Be care-

ful not to damage wall or mantel.

14. Place brass trim kit on the shoulder

screws located on the side and top of
the fireplace. Firmly snap the brass trim
over the shoulder screws on fireplace
(see Figure 13).

15. Adjust assembly to remove any gaps.

Attach remaining two 3" wood screws
from hardware pack through openings
inside of fireplace sides into the man-
tel. The openings are located at top be-
hind the area for the brass louvers (see
Figure 14).

16. Reinstall top brass louvers.

Mantel Clearances for Built-In
Installation

If placing mantel above built-in fireplace,
you must meet minimum clearance between
mantel shelf and top of fireplace opening.

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• raise the mantel to an accept-

able height

• remove the mantel

NOTICE: Surface temperatures of
adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch. If
installed properly, these tempera-
tures meet the requirement of the
national product standard. Fol-
low all minimum clearances
shown in this manual.

OPTIONAL MANTEL
INSTALLATION

Note:

 Refer to instructions provided with

the mantel for assembly instructions. Refer
to instructions below for system installa-
tion. Refer to instructions on page 4 for
firebox assembly. Blower accessory should
be installed if it is being used (see Accesso-
ries, 
page 26).

1.

Unscrew four brass screws that attach
top louver to fireplace. Remove louver
from fireplace and set aside.

2.

Place fireplace on wood base.

3.

Place mantel around fireplace/base
assembly.

4.

Assemble brass trim kit. See Assem-
bling Brass Trim
, page 11.

5.

Firmly snap brass trim kit on shoulder
screws. Shoulder screws are located on
fireplace cabinet (see Figure 13).

6.

Align brass trim kit for flush fit around
opening.

7.

Use two 3" wood screws provided and
attach fireplace base to wooden base
(see Figure 13).

8.

Remove brass trim kit and mantel. Be
careful not to damage wall or mantel.

 1 

3

/

4

" Screw

Wood Base

13"

16"

19"

21"

1

/

2

"

6"

8"

10"

Note:
All vertical
measurements
are from top of
fireplace
opening to 
bottom of
mantel shelf. All
measurements
are in inches.

Figure 12 - Minimum Mantel Clearances
for Built-In Installation

Mantel Shelf

Side of
Firebox

 WARNING: Do not allow non-

combustible materials to cover
any necessary openings like lou-
vered slots.

 WARNING: Use only noncom-

bustible mortar or adhesives
when overlapping the front fac-
ing with noncombustible facing
material.

 WARNING: Never modify or

cover the louvered slots on the
front of the firebox.

Hole for 3"
wood screw
for attaching
fireplace to
wooden base

Summary of Contents for VMH26TPB 14

Page 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or...

Page 2: ...Note During initial op eration slight smoking could occur due to log curing and fireplace burning manufacturing residues 8 To prevent the creation of soot follow the instructions in Cleaning and Main...

Page 3: ...wer gas bills Ignitor Button Screen Fireplace Cabinet Logs Control Knob IMPORTANT THIS PACKAGE CONTAINS A FIREPLACE HOOD UNWRAP CARTON AND REMOVE HOOD BEFORE DISCARDING PROTECTIVE PACKAGING 1 2 UNPACK...

Page 4: ...tallation in structions provided with blower 4 Remove log packaging material and discard packaging Gently place log set on burner support see Figure 3 The log should fit flat against top of burner sup...

Page 5: ...e atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable w...

Page 6: ...pliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maxi...

Page 7: ...stion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openin...

Page 8: ...ects are less than 36 inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas CAUTION This fireplace cre ateswarmaircurrents Thesecur r...

Page 9: ...oor Minimum 10 1 2 Figure 9 Rough Opening for Installing in Wall WARNING If pre wiring do not connect wiring to any electri cal source at this time Install fireplace electrical outlet and connect wiri...

Page 10: ...on Walls and mantels above the firebox may become hot to the touch If installedproperly thesetempera turesmeettherequirementofthe national product standard Fol low all minimum clearances shown in this...

Page 11: ...Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swinging the assembly down see Fig ure 17 2 Using short Phillips screwdriver re move the screw under the...

Page 12: ...rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 18 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect gree...

Page 13: ...Plug power cord to the outlet receptacle not provided as shown in figure 19 Wind the extra cable in power cord and and tie it up with the plastic wire strap see Figure 21 Set the cable bundle between...

Page 14: ...ly Propane LP Supply Tank External Regulator Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Theha...

Page 15: ...replace seeFigure25 The flexible gas supply line con nection to the equipment shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexibl...

Page 16: ...t all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a noncorrosiveleakdetectionfluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external r...

Page 17: ...e lightpilotwith match To light pilot with match see Manual Lighting Procedure page 18 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If...

Page 18: ...s 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow step 8 page 17 MANUAL LIGHTING PROCEDURE OPERATING FIREPLACE Continued OPERATING B...

Page 19: ...Blocked air holes will cre ate soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a quali fied service person Wealsorecommendthatyoukeep...

Page 20: ...ged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pie...

Page 21: ...ace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed ignition of burner Burner...

Page 22: ...ement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM...

Page 23: ...ll DESA International s Technical Service Department at 1 866 672 6040 for referral information When calling DESA International have ready your name your address modelandserialnumbersofyourfireplace h...

Page 24: ...LASSIC HEARTH FIREPLACE VMH26TPB ILLUSTRATED PARTS BREAKDOWN VMH26TPB 12 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 26 42 39 39 16 15 18 24 28 5 34 25 27 20 4 35 12 24 12...

Page 25: ...e 1 17 100587 01 Brass Screw 6 x 3 8 4 18 098303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 01CK Branch Support 1 21 099415 09 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23...

Page 26: ...ranunfinished birch ready to stain or paint Complete assemblyinstructionsincluded Three sided brass trim kit included EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT...

Page 27: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 28: ...or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the own...

Reviews: