Vanguard VGL850N Owner'S Operation And Installation Manual Download Page 9

9

105705

OWNER’S MANUAL

INSTALLATION

Continued

Installing 9-Volt Battery in Hand-
Held Remote Control Unit

1.

Remove battery cover on back of re-
mote control unit.

 2. Attach terminal wires to the battery

(not included). Place battery into the
battery housing. 

Note:

 Only use alka-

line battery.

3.

Replace battery cover onto remote con-
trol unit.

Figure 15 - Installing Battery in Hand-
Held Remote Control Unit

Battery
Cover

9-Volt
Battery

Terminal
Wires

Remote
Control Unit

Battery
Housing

Continued

 WARNING: All gas piping

and connections must be tested
for leaks after the installation is
completed.

After ensuring that the gas valve
is on, apply a soap and water
solution to all connections and
joints. If bubbles appear, leaks
can be detected and corrected.

Do not use an open flame for leak
testing and do not operate any
appliance if a leak is detected.

Complete your gas installation by connect-
ing incoming gas line with flexible gas line.
Secure tightly with wrench but Do NOT
Overtighten.

 CAUTION: Compounds used

on threaded joints of gas piping
shall be resistant to the action of
Liquefied Petroleum (LP or pro-
pane), and should be applied
lightly to ensure excess sealant
does not enter the gas line.

GAS LINE HOOK-UP

Figure 16 - Manual Shut-Off Valve
Installation

Figure 17 - Routing Incoming Gas Line

 WARNING: Gas line hookup

should be done by your gas sup-
plier or a qualified service person.

 WARNING: Before you pro-

ceed, make sure your gas supply
is OFF.

11"

(279mm)

5

/

8

"

(117mm)

5

/

8

"

(143mm)

1/2" NPT Incoming
Black Iron Gas
Line

Flexible Gas Line (1 Provided) Can Be
Extended Out from 3 Sides

Typical Exterior Wall Gas
Shut-Off Installation

 CAUTION: Do not kink flex-

ible gas line.

DESA recommends that a black iron gas
line be routed from the gas source, through
a sediment trap (shown in Figure 18), and
into the appliance,  Once connected through
the appliance, a flexible gas line may be
used for ease of installation to  gas control
valve (see Figure 19).

Before connecting the black iron gas line to the
inside of the appliance a sediment trap must be
included outside the appliance between the
gas line and the gas shut-off valve.  It must
extend down three (3) inches beyond the cen-
ter of the pipe.  Prepare incoming black iron
gas line with teflon tape or pipe joint com-
pound (Check with local building codes).

A manual shut-off valve has been  included
in the appliance’s gas supply system. You
may consider installing an extra gas shut-off
valve outside the appliance’s enclosure
(check with local codes) where it can be
accessed more conveniently with a key
through a wall as shown in Figure 16.

In conformance with local codes, route a 1/2”
NPT gas line towards the appliance coming
in from any of the 3 directions shown in
Figure 17.

Key

Extension

Shut-Off
Valve

3" Min.

(76mm)

Side W

all

Of Appliance

Incoming 1/2" Gas Line
Permitted by Local Codes

Sediment Trap
(Not Supplied)

Figure 18 - Sediment Trap

P

IL

O

T

ON

OFF

IN

OUT

Red Surface Indicates
For Propane/LP Use Only

Pilot Adj

Gas Shut-Off
Valve

Flexible Gas Line
Do NOT Kink

1/2" NPT
Incoming
Gas Line

Inlet
Pressure Tap

Outlet Pressure
Tap

Note:
1) Wire Connections
Not Shown for Clarity
2) * 1/8" NPT Plugged
Tapping

Figure 19 - Connecting Flexible Gas Line to Millivolt Valve

Summary of Contents for VGL850N

Page 1: ...mediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Page 2: ...2 572mm 9 5 8 244mm 27 689mm 10 3 4 273mm Left Side 9 3 4 248mm Right Side 13 330mm 2 3 8 60mm 32 813mm 33 13 16 859mm HEARTH AREA DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW FRONT INSIDE VIEW Fig...

Page 3: ...warranty will be voided by and DESA disclaims any responsibility for the following actions A Modification of the appliance or any of the components B Use of any component part not ap proved by DESA i...

Page 4: ...be yondanoutsidewall thiswouldalsoreduce the cutting of joists roof rafters and such Check local codes for any restrictions Projected installations can extend any distance into the room A projection...

Page 5: ...ppliance see Figure 17 page 9 Figure 7 Rough Opening for Installing in Wall Figure 8 Rough Opening for Corner Installation 41 7 8 1061mm 15 381mm 36 1 4 921mm 59 1 4 1505mm 29 5 8 752mm 21 3 16 538mm...

Page 6: ...vertical system height Codes also allows only one offset in the total system when at 60 de grees or greater The total vertical height in thisexamplerepresentstheminimumheight of 8 feet and therefore...

Page 7: ...c tion see Figure 10 VENTING INSTALLATION Continued If venting horizontally through a side wall becomes necessary a listed thimble ap proved for use with B type vent must be used Check with your local...

Page 8: ...ach the terminal wires to the battery see Figure 14 8 Replace access panel Place top of ac cess panel into opening and slide up Push bottom of access panel in and slide down to install Figure 13 Insta...

Page 9: ...ncoming Black Iron Gas Line Flexible Gas Line 1 Provided Can Be Extended Out from 3 Sides Typical Exterior Wall Gas Shut Off Installation CAUTION Do not kink flex ible gas line DESA recommends that a...

Page 10: ...t log piece into the notches on the right side of the front and rear logs see Figure 25 NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner could cause performance proble...

Page 11: ...s Ifthisisthecase pleaserequest help from someone else CAUTION For use with glass doorscertifiedwiththeappliance only CAUTION Do not operate theappliancewiththeglassdoor removed WARNING Children and a...

Page 12: ...GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instru...

Page 13: ...will not require such purging 1 When lit for the first time the appli ance will emit a slight odor for an hour or two This is due to the curing of the logs and burn in of internal paints and lubrican...

Page 14: ...rgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier WIRING DIAGRAM Pilot Burner Pilot Gas Line Thermopile Note Use only original replacement parts This will prot...

Page 15: ...or sensor not gen erating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in the PILOT posi...

Page 16: ...lot lights turn off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the improper lighting and a longer purge period is recommended If pilot will not light che...

Page 17: ...f page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner...

Page 18: ...485 105860 02 If in need of replacing have a qualified technician replace it GAS CONTROL VALVE Natural 14512 105861 01 Propane LP 14513 105861 02 If in need of replacing have a qualified technician re...

Page 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 20: ...he responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...