Vanguard UNVENTED (VENT-FREE) NATURAL  GAS LOG HEATER Operating And Installation Manual Download Page 12

12

105273

UNVENTED NATURAL GAS LOG HEATER

VANGUARD FLAME MAX

®

INSTALLATION

Continued

CONNECTING TO GAS
SUPPLY

NOTICE: A qualified service per-
son must connect heater to gas
supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have
the items listed below.

• piping (check local codes)

• sealant (resistant to LP gas)

• manual shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

*  An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 25.

 CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
pressure will occur.

 WARNING: Never connect

heater to private (non-utility) gas
wells. This gas is commonly
known as wellhead gas.

 CAUTION: Avoid damage to

control. Hold gas fitting with
wrench when connecting it to gas
piping and/or fittings.

Install sediment trap in supply line as shown
in Figure 13. Locate sediment trap where it
is within reach for cleaning. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into heater controls. If sediment trap
is not installed or is installed wrong, heater
may not run properly.

Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
heater (see Figure 13).

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged heater valves.

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

Figure 13 - Gas Connection

* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

** Minimum inlet pressure for purpose of input adjustment.

3" Minimum

Gas Control

From Gas Meter (5"
W.C.** to 10.5" W.C.
Pressure)

A.G.A. Design-Certified
Manual Shutoff Valve With
1/8" NPT Tap*

Approved Flexible Gas
Hose (if allowed by
local codes)

Tee Joint

Cap

Sediment
Trap

Pipe Nipple

Summary of Contents for UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER

Page 1: ...cy or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Re...

Page 2: ...ore operating heater 7 You must operate this heater with a fire placescreeninplace Makesurefireplace screen is closed before running heater 8 This log heater is designed to be smoke less If logs ever...

Page 3: ...oduct information 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by the burner This could damage heater Always handle base assembly by grate 2 Remove all...

Page 4: ...thods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home ownerswanttheirhomesasairtigh...

Page 5: ...ustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ____________Btu Hr maximum the space can support _______...

Page 6: ...l connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Co...

Page 7: ...heatersaddmois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Com bustion and Ventila...

Page 8: ...essory GA6050 GA6052 or GA6053 see Acces sories page 25 18 Model Noncombustible material OK Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot...

Page 9: ...lf 12 8 A 18 8 20 14 22 163 4 24 20 All minimum distances are in inches Log Set 24 30 36 Models 18 Model 2 1 2 6 8 10 Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inche...

Page 10: ...fireplace with a working flue and constructed of non combustible material Ifyourheaterisamanuallycontrolledmodel you may use this heater as a vented product There are three reasons for operating your...

Page 11: ...regulator of heater see Figure 11 IMPORTANT Hold gas regulator with wrench when connecting flexible gas hose 2 Locate two masonry screws in hard ware package 3 Place heater base in fireplace 4 Place...

Page 12: ...fitting with wrenchwhenconnectingittogas piping and or fittings Installsedimenttrapinsupplylineasshown in Figure 13 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap whe...

Page 13: ...In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas p...

Page 14: ...16 Installing Golden Oak One Piece Log Set Figure 17 Installing Golden Oak One Piece Log Set Top View WARNING Failure to posi tion the parts in accordance with these diagrams or failure to use only p...

Page 15: ...ff a paper burning smell Open damper or window to vent smell This will only last a few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all...

Page 16: ...o turn the burner on and off When turning burner off the pilot will remain lit GHRCT Operation 2b Select the MAN manual or AUTO button on the hand held remote con trol unit see Figure 21 page 17 In ma...

Page 17: ...t tern Figure23showsanincorrectpilotflame pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools the heater will shut down...

Page 18: ...older for dust and dirt see Figure 24 3 Blow air through the ports slots and holes in the burner Figure 24 Injector Holder On Outlet Burner Tube Burner Tube Injector Holder May Be Brass or Aluminum De...

Page 19: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Page 20: ...requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum...

Page 21: ...er burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common w...

Page 22: ...MAX GOLDEN OAK LOG MODELS VYD18NRA VYD24NRA VYD30NRA AND VYD36NR 4 13 13 14 22 13 8 18 7 6 9 1 12 5 16 15 17 3 11 2 10 24 23 23 19 19 20 21 26 25 O F F P I L O T O N H I L O O F F P I L O T O N H I L...

Page 23: ...84 38 Screw 8 x 38 7 14 104384 01 102775 06CK 102775 08CK 102775 08CK Painted Base Assy 1 15 098271 07 098271 07 098271 07 098271 07 Ignitor Cable 1 16 102445 01 102445 01 102445 01 102445 01 Piezo Ig...

Page 24: ...FICATIONS Golden Oak Golden Oak 18 Remote 24 30 and 36 Ready Remote Ready Btu Variable 16 000 30 000 20 000 39 000 Type Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Pressure Manifold 3 5...

Page 25: ...8 wide MANUAL SHUTOFF VALVE GA5010 Forallmodels Manualshutoffvalvewith1 8 NPT tap Fits 1 2 NPT pipe AUTO MAN OFF STA TUS ON LO HI TEMP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT For al...

Page 26: ...to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER E...

Reviews: