background image

12

103661

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at
1-800-323-5190.

Note:

 Use only original replacement parts. This will protect your warranty coverage

for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement
part(s), call DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

• your name
• your address
• model number of your stove
• how stove was malfunctioning
• type of gas used (propane or natural gas)
• purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement
part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral
information.

When calling DESA International, have ready

• model number of your stove
• the replacement part number

REPLACEMENT

PARTS

ACCESSORIES

Purchase these stove accessories from your local dealer. If they can not supply these
accessories, call DESA International’s Sales Department at 1-800-432-2382 for
information. You can also write to the address listed on the back page of this manual.

BLOWER ACCESSORY - GA3700

The variable blower allows you to select
the desired speed. The blower circulates
heated air from the stove into the room.

MANUAL SHUTOFF VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap.

Summary of Contents for SVFBC

Page 1: ...enance can cause injury or property damage Refer to this manual for correct installa tion and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING The SVFBC stove is to be used only with certain vent free gas log heaters see Table 1 Do not burn wood or other materials in this stove This stove may be installed in an...

Page 2: ...king 5 Product Features 6 Locating Stove 6 Air for Combustion and Ventilation 6 Installing 10 Installation Clearances 10 Installing GA3700 Blower Accessory 11 Installing Log Heater in Stove 11 Technical Service 12 Replacement Parts 12 Accessories 12 Illustrated Parts Breakdown 13 Warranty Information Back Cover For use with vent free gas log heater models TABLE 1 VANGUARD VL18N VL18P VL18NT A VL18...

Page 3: ...talledinthisstoverequirefreshairventilationtorun properly See Air for Combustion and Ventilation pages 6 through 9 9 Do not run stove where flammable liquids or vapors are used or stored under dusty conditions 10 Do not use this stove to cook food or burn paper or other objects 11 Never place any objects in the stove or on logs 12 Stove front and screen becomes very hot when running the stove Keep...

Page 4: ...1 PRODUCT SPECIFICATIONS Figure 1 Stove Front View Figure 2 Stove Side View 28 26 1 2 18 1 2 19 27 16 5 8 24 20 1 4 Door Handle 22 3 4 1 31 1 2 1 7 3 4 15 1 2 19 1 2 1 1 2 1 1 4 14 1 2 18 1 2 4 1 12 13 1 2 16 ...

Page 5: ...n Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Cut tape at top of carton Remove stove by lifting it out of the top of carton 2 Check carton contents for the following Stove Touch up paint PRODUCT SPECIFICATIONS Continued Figure 3 Stove Top View 28 15 1 2 4 5 3 4 NOTICE Keep stove upright when removing from carton Never turn stove on its side WARNING ICON G 001 CAUTION Before insta...

Page 6: ...ate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances LOCATING STOVE Planning Plan where you will install the stove This will save time and money later when you install the stove Before installation consider the following 1 Where the stove will be located Allow for wall and ceiling clearances see Installation Clearances page ...

Page 7: ...ing or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of the three criteria above you must provide additional fresh air See Ventilation Air From Outdoors page 9 If your home does not meet all of...

Page 8: ...00 Btu Hr Total 70 000 Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 63 300 Btu Hr maximum the space can support 7...

Page 9: ...bined spaces must have enough fresh air to supply all appliances in both spaces Figure 5 Ventilation Air from Outdoors Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces ...

Page 10: ...e front top or sides of the stove in high traffic areas in windy or drafty areas WARNING ICON G 001 CAUTION Log heaters installed in this stove create warm air currents These currents move heat to wall surfaces next to stove Installing stove next to vinyl or cloth wall coverings or operating stove where impuri ties in the air such as tobacco smoke exist may discolor walls WARNING ICON G 001 CAUTIO...

Page 11: ...n log set owner s manual NOTICE Most building codes do not permit concealed gas connections A flexible gas line is provided to allow accessibility from the stove The manual shutoff valve should be accessible INSTALLING LOG HEATER IN STOVE WARNING ICON G 001 CAUTION Do not pick up log base assembly by burners This could damage burners Only handle base by grates 1 If installing GA3700 Blower Accesso...

Page 12: ...purchase date Usually we will ask you to return the defective part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready model number of your stove the replacement part number REPLACEMENT PARTS...

Page 13: ... page 12 of this manual KEY NO PART NUMBER DESCRIPTION QTY 1 103657 01 Door includes 5 screws and Handle 1 2 103693 01 Button Plug 1 3 103659 01 Brass Trim Kit upper and lower includes 6 screws 2 4 103660 01 Door Latch Kit includes 2 screws 1 PARTS AVAILABLE NOT SHOWN 103662 01 Touch Up Paint 1 Model SVFBC ILLUSTRATED PARTS BREAKDOWN 1 3 3 4 2 ...

Page 14: ..._________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ _______________________...

Page 15: ..._________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ _______________________...

Page 16: ...her costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THREE 3 YEARS ON ALL CO...

Reviews: