18
106497
DIRECT-VENT FIREPLACE
®
OFF
P
IL
O
T
ON
PI
LOT
E
A
16AI
7
TPTH
TP
TH
Figure 35 - Wall Switch Wiring Diagram
WARNING: Do not wire remote
wall switch to main power supply
(Standard 120v household current).
WALL SWITCH INSTALLATION
Since the fireplaces use a valve that operates
on millivolt current generated by the pilot, a
wall switch (not included) may be used to
activate the gas control valve without the
use of normal household electricity. A hand-
held, ON/OFF remote control is standard
with this unit. Wall switch is optional. If the
wall switch is installed, the hand-held, ON/
OFF remote cannot be used.
1.
To remove the louvers, simultaneously
pull both top end spring latches towards
the center of the appliance until they
are disengaged from locating holes.
Repeat for bottom end spring latches
and pull outward. Reverse the proce-
dure to install louvers back onto the
appliance (see Figure 34).
2.
Connect the 18 ga. wires from wall
switch (not included) to the gas con-
trol valve and microswitch, as shown
in Figure 35.
Route Millivolt Wires (Supplied)
Through Gas Line Conduit Sleeve
To Thermopile
(Back View)
Note:
If any of the original wire supplied must be replaced, use type 18 AWG-105 degree
C (25 feet length MAXIMUM) or equivalent.
Figure 34 - Removing Louver
Glass
Locating
Holes
Spring
Latch
Note: This unit does
not have a HI/LOW
feature
Gas Valve
FIREPLACE
INSTALLATION
Continued
Figure 36 - Installing Remote Receiver
(Shown from Rear of Mounting Bracket)
Figure 37 - Installing Battery in Receiver
Battery Clip
9-Volt Battery
Receiver
Terminal
Wires
Receiver
Mounting
Bracket
Plastic
Mounting
Clips
Installing 9-Volt Alkaline Battery in
Hand-Held Remote Control Unit
1.
Remove battery cover on back of re-
mote control unit.
2.
Attach terminal wires to the battery
(not included). Place battery into the
battery housing.
3.
Replace battery cover onto remote con-
trol unit.
Figure 38 - Installing Battery in Hand-
Held Remote Control Unit
Battery
Cover
9-Volt
Battery
Terminal
Wires
Remote
Control Unit
Battery
Housing
WIRELESS HAND-HELD
REMOTE CONTROL (GHRC
SERIES) INSTALLATION
Note:
If using the wireless hand-held re-
mote control, the wall switch is no longer
operational.
NOTICE: Only use alkaline bat-
teries (not included, requires 2).
Installing Receiver
Note:
Receiver is preinstalled.
1.
Remove access panel from lower front
face of firebox. Lift straight up on ac-
cess panel until it stops. Pull bottom of
access panel forward, then down.
2.
Disconnect wall switch wires from TH
and TPTH terminals on control valve
(see Figure 35).
3.
Install remote receiver unit onto mount-
ing bracket using the two plastic mount-
ing clips (see Figure 36).
4.
Connect wires to control valve. Con-
nect white wire to terminal TH. Con-
nect red wire to terminal TPTH.
5.
Locate the battery clip mounted on the
back of the receiver (see Figure 37).
6.
Slide 9-volt battery (not included)
through the clip.
7.
Attach the terminal wires to the battery
(see Figure 37).