Vanguard Firewerks VFRMV18NA Owner'S Operation And Installation Manual Download Page 18

www.desatech.com

114745-01B

18

OPERATING HEATER

Continued 

MANUAL LIGHTING 

PROCEDURE

1.  Follow steps 1 through 6 under 

Lighting 

Instructions

, page 16.

2.  Depress control knob and light pilot with 

match. 

3.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob. Now follow steps 9 through 

11, 

Lighting Instructions

, page 17.

OPTIONAL HAND-HELD 

REMOTE OPERATION

Note:

 All remote control accessories must be 

purchased separately (see 

Accessories

, page 

26).  Follow  instructions  included  with  the 

remote control.

NOTICE: You must light the pilot 

before using the hand-held re-

mote control unit. See 

Lighting 

Instructions

 on page 16.

After lighting, let pilot flame burn for about 

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere 

between HI and LO. Slide the selector switch 

to  the  REMOTE  position  (see  Figure  19).  

Note: 

The  burner  may  light  if  hand-held 

remote was on when selector switch was last 

turned off. You can now turn the burner on and 

off with the hand-held remote control unit. 

IMPORTANT:

 Do not leave the selector switch 

in the REMOTE or ON position when the pilot 

is not lit. This will drain the battery.

Figure 19 - Setting the Selector Switch, 

Control Knob and Flame Adjustment 

Knob for Remote Operation 

REMOTE
OFF
ON

Piezo 
Ignitor

Selector Switch in 
REMOTE Position

Control 
Knob

Flame Adjustment 
Knob

ON/OFF SERIES (MODEL GHRCB)

Hold  the  control  button  on  the  hand-held 

remote until burner turns on. Hold the con-

trol button again until burner turns off (see 

Figure 20).

To  Lock

  press  both  buttons  on  hand-held 

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is 

on it will be turned off automatically. In the 

locked state, the light will not light up when 

any button is pressed. 

To Unlock

 press both buttons together on hand-

held remote control until the light stops flashing. 

The hand-held remote is now unlocked.

Figure 20 - On/Off Hand-Held Remote 

Control Unit (GHRCB)

Control Button 
Turns Burners 
On and Off

THERMOSTAT SERIES (MODEL 
GHRCTB)

The hand-held remote can be operated using ei-

ther the manual mode (MANU) or thermostatic 

mode (AUTO) (see Figure 21, page 19). To select 

Fahrenheit/Centigrade mode display, carefully 

press the ˚C/˚F mode button with the end of a 

paper clip or similar blunt object.

Manual Mode

1.  Press  the  POWER  and  LOCK  buttons 

together to turn on the hand-held remote 

control.

2.  Press  the  MANU  button  to  turn  on  the 

fireplace.

3.  Press  the  POWER  and  LOCK  buttons 

together to turn off the fireplace.

Auto (Thermostatic) Mode

1.  Press  the  POWER  and  LOCK  buttons 

together to turn on the hand-held remote 

control.

2.  Press AUTO button to select this mode.

3.  Set the desired room temperature by press-

ing the TEMP + or - buttons.

4.  Press  the  POWER  and  LOCK  buttons 

together to turn off the fireplace. 

Summary of Contents for Firewerks VFRMV18NA

Page 1: ...y to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cann...

Page 2: ...in which it is installed Provi sions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 6 of this manual This appliance may be in...

Page 3: ...ion of this log set WARNING Any change to this log set or its controls can be dangerous WARNING Donotuseablow erinsert heatexchangerinsertor otheraccessorynotapprovedfor use with this appliance WARNIN...

Page 4: ...and Maintenance page 20 SAFETY INFORMATION Continued 8 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white...

Page 5: ...There are four optional remote controls that can be purchased separately Wall switch Hand held ON OFF remote Wall thermostat Hand held thermostat remote See Accessories page 26 Thewallthermostatorhand...

Page 6: ...provide additional fresh air Unusually tight construction is de ned as construction where a Walls and ceilings exposed to the out side atmosphere have a continuous water vapor retarder with a rating o...

Page 7: ...ATION Continued The space in the previous example is a con ned space because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your opt...

Page 8: ...entilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 INSTALLATION NOTICE This heater is intended for use as supplemental heat Use this heater along with...

Page 9: ...P for your unit If your gas supply is not correct do not install in replace Call dealer where you bought the appliance for proper type of appliance INSTALLATION Continued WARNING This appliance is equ...

Page 10: ...terial A Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace Noncombustible Requirements for Material Distance A Safe Installation 12 or more N o n c o m b u s t i b l e material OK...

Page 11: ...Minimum Non Combustible Material 8 Min 14 1 2 18 5 8 22 1 2 All minimum distances are in inches 26 2 1 2 6 8 10 12 Distances to Underside of Mantel Hood GA6050 GA6052 or GA6053 Top of Fireplace Openin...

Page 12: ...Clamp Damper Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Damper Clamp Damper See chart below for minimum permanent ue opening you must provide Attach damper clamp so the minimum perm...

Page 13: ...s Needed Before installing heater make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valv...

Page 14: ...rom going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly INSTALLATION Continued CAUTION Avoid damage to gas control Hold gas control with wren...

Page 15: ...as or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to e...

Page 16: ...pect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If replace has glass doors never operate this heater with...

Page 17: ...act a quali ed service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 page 16 OPERATING HEATER Continued Figure 17 Control Knob and Ignitor Button Location Manual C...

Page 18: ...Selector Switch in REMOTE Position Control Knob Flame Adjustment Knob ON OFF SERIES MODEL GHRCB Hold the control button on the hand held remote until burner turns on Hold the con trol button again un...

Page 19: ...ly receives signals from the hand held remote to control the room temperature If the hand held remote is misplaced obstructed or for any reason cannot transmit to the receiver the receiver will shut o...

Page 20: ...trol areas burners and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a quali ed service person Heater may need more frequent...

Page 21: ...er repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot ame indicates dust and dirt in the pilot as sembly There is a small pilot air inlet hole about two inches from where the...

Page 22: ...LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut hold...

Page 23: ...nob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas company B C...

Page 24: ...ion and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see pages...

Page 25: ...logged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Hand...

Page 26: ...as purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can tsupplyoriginalreplacementpart s callDESA at...

Page 27: ...ws the gas log heater to be turned on and off by using a hand held remote control ACCESSORIES Continued FB36CA FB42C SERIES CIRCULATING FB36NCA FB42NC SERIES NON CIRCULATING Not Shown For all models D...

Page 28: ...www desatech com 114745 01B 28 ILLUSTRATED PARTS BREAKDOWN VFRMV18NA VFRMV18PA VFRMV24NA Shown VFRMV24PA 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24 24 24 24 24 24 5 25 26 27...

Page 29: ...114793 01 114793 01 114793 01 Piezo Switch Bracket 1 14 097159 04 097159 04 097159 04 097159 04 Piezo 1 15 14579 14579 14579 14579 Rocker Switch 1 16 111817 01 111817 01 111817 01 111817 01 Main Gas L...

Page 30: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 32: ...r MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because...